C H A PT E R
2
System Overview and Troubleshooting
This chapter provides information that is required in troubleshooting.
This information is explained in the following sections:
■
Section 2.1, “System Views” on page 2-1
■
Section 2.2, “Labels” on page 2-11
■
Section 2.3, “Operator Panel” on page 2-17
■
Section 2.4, “Determining Which Diagnostics Methods To Use” on page 2-21
■
Section 2.5, “Checking the Server and System Configuration” on page 2-23
■
Section 2.6, “Error Conditions” on page 2-26
■
Section 2.7, “LED Error Display” on page 2-30
■
Section 2.8, “Using the Troubleshooting Commands” on page 2-34
■
Section 2.9, “Traditional Oracle Solaris Troubleshooting Commands” on page 2-37
2.1
System Views
This section provides views of the high-end server. The figures can be used to locate the
component in the server to be subjected to maintenance.
In terms of its structure, the high-end server consists of a cabinet that includes various
mounted components and a front door, rear door, and side covers that protect the mounted
components. The side covers are removed when cabinets are connected to each other or when
the dual power feed option is connected to the cabinet. The operator panel, which is mounted
on the front door, is always accessible. Each door can be locked with a key so that only the
administrator can open it.
The front and rear views of
,
,
, and
include names and abbreviations for field-replaceable units (FRUs). Components
that are mounted inside the system are shown
, and
. The
abbreviations are used in messages and the like. If multiple FRUs of the same type are
mounted, the number sign # and a sequential number is added to their names to distinguish
Summary of Contents for SPARC Enterprise M8000
Page 4: ......
Page 15: ...Contents xv Index Index 1 ...
Page 16: ...xvi SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 22: ......
Page 27: ...Chapter 1 Safety and Tools 1 5 M9000 Server Front View ...
Page 29: ...Chapter 1 Safety and Tools 1 7 Power Supply Unit PSU ...
Page 38: ...1 16 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 88: ...2 50 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 148: ......
Page 154: ...5 6 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 205: ...Chapter 7 I O Unit IOU Replacement 7 13 FIGURE 7 8 Removing the IOU Front of M9000 1 1 2 3 ...
Page 227: ...Chapter 8 FAN Unit Replacement 8 11 FIGURE 8 9 Removing the FAN Unit Rear of M8000 1 2 ...
Page 256: ...10 8 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 272: ...11 16 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 312: ...13 30 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 340: ...15 14 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 358: ...17 10 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 370: ...18 12 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 380: ...19 10 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 409: ...Chapter 20 Backplane Replacement 20 29 FIGURE 20 16 Removing the FANBP Rear of the M8000 ...
Page 422: ...21 10 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 439: ...Chapter 23 Switch Backplane Replacement 23 7 FIGURE 23 4 Removing the SWBP Rear of the M8000 ...
Page 442: ...23 10 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 460: ...24 18 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 484: ...25 24 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 494: ...A 10 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 544: ...C 4 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...
Page 552: ...D 8 SPARC Enterprise M8000 M9000 Servers Service Manual October 2012 ...