5-22
SPARC Enterprise T1000 Server Service Manual • April 2007
■
If the fault is a
host-detected fault
(displays
a
UUID), continue to
. For
example:
■
If the fault resulted in the FRU being disabled, such as the following,
then run the
enablecomponent
command to enable the FRU:
8. Perform the following steps to verify the repair:
a. Set the virtual keyswitch to
diag
so that POST will run in Service mode.
sc>
showfaults -v
ID Time FRU Fault
0 SEP 09 11:09:26 MB/CMP0/CH0/R0/D0 Host detected fault
MSGID:
SUN4V-8000-DX UUID: f92e9fbe-735e-c218-cf87-9e1720a28004
sc>
showfaults -v
ID Time FRU Fault
1 OCT 13 12:47:27 MB/CMP0/CH0/R0/D0 MB/CMP0/CH0/R0/D0
deemed faulty and disabled
sc>
enablecomponent MB/CMP0/CH0/R0/D0
sc>
setkeyswitch diag