Chapter 3
Server Diagnostics
3-17
■
Example showing a fault that was detected by POST. These kinds of faults are
identified by the message
deemed faulty and disabled
and by a FRU name.
■
Example showing a fault that was detected by the PSH technology. These kinds of
faults are identified by the text
Host detected fault
and by a UUID.
3.3.3
Running the
showenvironment
Command
The
showenvironment
command displays a snapshot of the server’s
environmental status. This command displays system temperatures, hard disk drive
status, power supply and fan status, front panel LED status, voltage and current
sensors. The output uses a format similar to the Solaris OS command
prtdiag
(1m).
●
At the
sc>
prompt, type the
showenvironment
command.
The output differs according to your system’s model and configuration. Example:
sc>
showfaults -v
ID Time FRU Fault
1 OCT 13 12:47:27
MB/CMP0/CH0/R1/D0 MB/CMP0/CH0/R1/D0 deemed
faulty and disabled
sc>
showfaults -v
ID Time FRU Fault
0 SEP 09 11:09:26
MB/CMP0/CH0/R1/D0 Host detected fault, MSGID:
SUN4U-8000-2S UUID: 7ee0e46b-ea64-6565-e684-e996963f7b86
sc>
showenvironment
=============== Environmental Status ===============
--------------------------------------------------------------------------------
System Temperatures (Temperatures in Celsius):
--------------------------------------------------------------------------------
Sensor Status Temp LowHard LowSoft LowWarn HighWarn HighSoft HighHard
--------------------------------------------------------------------------------
MB/T_AMB OK 28 -10 -5 0 45 50 55
MB/CMP0/T_TCORE OK 50 -10 -5 0 85 90 95
MB/CMP0/T_BCORE OK 51 -10 -5 0 85 90 95
MB/IOB/T_CORE OK 49 -10 -5 0 95 100 105
--------------------------------------------------------
System Indicator Status:
--------------------------------------------------------
Summary of Contents for SPARC ENTERPRISE T1000
Page 1: ......
Page 2: ......
Page 6: ......
Page 11: ...Contents ix Index Index 1 ...
Page 12: ...x SPARC Enterprise T1000 Server Service Manual April 2007 ...
Page 16: ...xiv SPARC Enterprise T1000 Server Service Manual April 2007 ...
Page 25: ...Preface xxiii Reader s Comment Form ...
Page 32: ...2 4 SPARC Enterprise T1000 Server Service Manual April 2007 ...
Page 35: ...Chapter 3 Server Diagnostics 3 3 FIGURE 3 1 Diagnostic Flow Chart flow chart ...
Page 86: ...3 54 SPARC Enterprise T1000 Server Service Manual April 2007 ...
Page 126: ...A 4 SPARC Enterprise T1000 Server Service Manual April 2007 ...
Page 130: ...Index 4 SPARC Enterprise T1000 Server Service Manual April 2007 ...
Page 131: ......
Page 132: ......