3-40
SPARC Enterprise T1000 Server Service Manual • April 2007
provides a fault notification with a message ID (MSGID). You can use the message
ID to get additional information about the problem from Sun’s knowledge article
database.
The Predictive Self-Healing technology covers the following server components:
■
UltraSPARC® T1 multicore processor
■
Memory
■
I/O bus
The PSH console message provides the following information:
■
Type
■
Severity
■
Description
■
Automated response
■
Impact
■
Suggested action for system administrator
If the Solaris PSH facility detects a faulty component, use the
fmdump
command to
identify the fault. Faulty FRUs are identified in fault messages using the FRU name.
For a list of FRU names, see
Note –
Additional Predictive Self-Healing information is available at:
3.5.1
Identifying PSH Detected Faults
When a PSH fault is detected, a Solaris console message similar to the following is
displayed:
SUNW-MSG-ID: SUN4V-8000-DX, TYPE: Fault, VER: 1, SEVERITY: Minor
EVENT-TIME: Wed Sep 14 10:09:46 EDT 2005
PLATFORM: SPARC-Enterprise-T1000, CSN: -, HOSTNAME: wgs48-37
SOURCE: cpumem-diagnosis, REV: 1.5
EVENT-ID: f92e9fbe-735e-c218-cf87-9e1720a28004
DESC: The number of errors associated with this memory module has exceeded
acceptable levels. Refer to http://sun.com/msg/SUN4V-8000-DX for more
information.
AUTO-RESPONSE: Pages of memory associated with this memory module are being
removed from service as errors are reported.
IMPACT: Total system memory capacity will be reduced as pages are retired.
REC-ACTION: Schedule a repair procedure to replace the affected memory module.
Use fmdump -v -u <EVENT_ID> to identify the module.
Summary of Contents for SPARC ENTERPRISE T1000
Page 1: ......
Page 2: ......
Page 6: ......
Page 11: ...Contents ix Index Index 1 ...
Page 12: ...x SPARC Enterprise T1000 Server Service Manual April 2007 ...
Page 16: ...xiv SPARC Enterprise T1000 Server Service Manual April 2007 ...
Page 25: ...Preface xxiii Reader s Comment Form ...
Page 32: ...2 4 SPARC Enterprise T1000 Server Service Manual April 2007 ...
Page 35: ...Chapter 3 Server Diagnostics 3 3 FIGURE 3 1 Diagnostic Flow Chart flow chart ...
Page 86: ...3 54 SPARC Enterprise T1000 Server Service Manual April 2007 ...
Page 126: ...A 4 SPARC Enterprise T1000 Server Service Manual April 2007 ...
Page 130: ...Index 4 SPARC Enterprise T1000 Server Service Manual April 2007 ...
Page 131: ......
Page 132: ......