6
SPARC Enterprise T2000 Server Administration Guide • April 2007
For instructions on accessing the system console through a terminal server, see
“Accessing the System Console Through a Terminal Server” on page 10
For instructions on accessing the system console through an alphanumeric terminal,
see
“Accessing the System Console Through an Alphanumeric Terminal” on page 15
For instructions on accessing the system console through a Tip line, see
the System Console Through a Tip Connection” on page 12
On your server, the system console comes preconfigured to allow input and output
only by means of the system controller. The system controller must be accessed
either through the serial management port (SER MGT) or the network management
port (NET MGT). By default, the network management port is configured to retrieve
network configuration using DHCP and to allow connections using SSH. You can
modify the network management port configuration after connecting to ALOM CMT
through either the serial or network management ports. For more information, see
“Activating the Network Management Port” on page 8
Alternative System Console Configuration
In the default configuration, system controller alerts and system console output
appear interspersed in the same window.
After initial system installation
, you can
redirect the system console to take its input from and send its output to a graphics
card’s port.
For the following reasons, the best practice is to leave the console port in its default
configuration:
■
In a default configuration, the serial management and network management ports
enable you to open up to eight additional windows through which you can view,
but not affect, system console activity. You cannot open these connections if the
system console is redirected to a graphics card’s port.
■
In a default configuration, the serial management and network management ports
enable you to switch between viewing system console and system controller
output on the same device by typing a simple escape sequence or command. The
escape sequence and command do not work if the system console is redirected to
a graphics card’s port.
■
The system controller keeps a log of console messages, but some messages are not
logged if the system console is redirected to a graphic card’s port. The omitted
information could be important if you need to contact customer service with a
problem.
You change the system console configuration by setting OpenBoot configuration
variables. See
“System Console OpenBoot Configuration Variable Settings” on
Summary of Contents for SPARC Enterprise T2000
Page 1: ......
Page 2: ......
Page 6: ......
Page 12: ...x SPARC Enterprise T2000 Server Administration Guide April 2007 ...
Page 14: ...xii SPARC Enterprise T2000 Server Administration Guide April 2007 ...
Page 20: ...xviii SPARC Enterprise T2000 Server Administration Guide April 2007 Reader s Comment Form ...
Page 22: ...xx SPARC Enterprise T2000 Server Administration Guide April 2007 ...
Page 66: ...44 SPARC Enterprise T2000 Server Administration Guide April 2007 ...
Page 88: ...66 SPARC Enterprise T2000 Server Administration Guide April 2007 ...
Page 92: ...70 SPARC Enterprise T2000 Server Administration Guide April 2007 ...
Page 97: ......
Page 98: ......