60
SPARC Enterprise T2000 Server Administration Guide • April 2007
▼
To Perform a Mirrored Disk Hot-Plug Operation
1. Verify which hard drive corresponds with which logical device name and physical
device name.
See
“Disk Slot Numbers, Logical Device Names, and Physical Device Names” on
2. To confirm a failed disk, type the following command:
If the Disk Status is FAILED, then the drive can be removed and a new drive
inserted. Upon insertion, the new disk should be OK and the volume should be
RESYNCING.
For example:
This example indicates that the disk mirror has degraded due to a failure in disk
c0t2d0
.
Note –
The logical device names might appear differently on your system,
depending on the number and type of add-on disk controllers installed.
3. Remove the hard drive, as described in the
SPARC Enterprise T2000 Server Service
Manual.
There is no need to issue a software command to bring the drive offline when the
drive has failed.
4. Install a new hard drive, as described in the
SPARC Enterprise T2000 Server Service
Manual.
The RAID utility automatically restores the data to the disk.
#
raidctl
#
raidctl
RAID Volume RAID RAID Disk
Volume Type Status Disk Status
--------------------------------------------------------
c0t1d0
IM
DEGRADED
c0t1d0
OK
c0t2d0
FAILED
Summary of Contents for SPARC Enterprise T2000
Page 1: ......
Page 2: ......
Page 6: ......
Page 12: ...x SPARC Enterprise T2000 Server Administration Guide April 2007 ...
Page 14: ...xii SPARC Enterprise T2000 Server Administration Guide April 2007 ...
Page 20: ...xviii SPARC Enterprise T2000 Server Administration Guide April 2007 Reader s Comment Form ...
Page 22: ...xx SPARC Enterprise T2000 Server Administration Guide April 2007 ...
Page 66: ...44 SPARC Enterprise T2000 Server Administration Guide April 2007 ...
Page 88: ...66 SPARC Enterprise T2000 Server Administration Guide April 2007 ...
Page 92: ...70 SPARC Enterprise T2000 Server Administration Guide April 2007 ...
Page 97: ......
Page 98: ......