Chapter 3
Managing Disk Volumes
63
Note that while you can use the Solaris OS
cfgadm install_device
and
cfgadm
remove_device
commands to perform a hard drive hot-swap procedure, these
commands issue the following warning message when you invoke these commands
on a bus containing the system disk:
This warning is issued because these commands attempt to quiesce the (SAS) SCSI
bus, but the SPARC Enterprise T2000 server firmware prevents it. This warning
message can be safely ignored in the SPARC Enterprise T2000 server, but the
following step avoids this warning message altogether.
3. Remove the hard drive from the device tree.
To remove the hard drive from the device tree, type the following command:
For example:
This example removes
c0t3d0
from the device tree. The blue OK-to-Remove LED
lights.
#
cfgadm -x remove_device c0::dsk/c0t1d0
Removing SCSI device: /devices/pci@1f,4000/scsi@3/sd@1,0
This operation will suspend activity on SCSI bus: c0
Continue (yes/no)? y
dev = /devices/pci@780/pci@0/pci@9/scsi@0/sd@1,0
cfgadm: Hardware specific failure: failed to suspend:
Resource Information
------------------ -------------------------
/dev/dsk/c0t0d0s0 mounted filesystem "/"
/dev/dsk/c0t0d0s6 mounted filesystem "/usr"
#
cfgadm -c unconfigure
Ap-Id
#
cfgadm -c unconfigure c0::dsk/c0t3d0
Summary of Contents for SPARC Enterprise T2000
Page 1: ......
Page 2: ......
Page 6: ......
Page 12: ...x SPARC Enterprise T2000 Server Administration Guide April 2007 ...
Page 14: ...xii SPARC Enterprise T2000 Server Administration Guide April 2007 ...
Page 20: ...xviii SPARC Enterprise T2000 Server Administration Guide April 2007 Reader s Comment Form ...
Page 22: ...xx SPARC Enterprise T2000 Server Administration Guide April 2007 ...
Page 66: ...44 SPARC Enterprise T2000 Server Administration Guide April 2007 ...
Page 88: ...66 SPARC Enterprise T2000 Server Administration Guide April 2007 ...
Page 92: ...70 SPARC Enterprise T2000 Server Administration Guide April 2007 ...
Page 97: ......
Page 98: ......