Powering On the System
55
Note –
After setting the configuration parameters, you must enter the
set
/SP/network commitpending=true
command for the new values to take affect.
3. Commit the changes to the service processor network parameters.
Note –
You can run the
show /SP/network
command again (after performing the
set /SP/network commitpending=true
command) to verify that the
parameters have been updated.
Related Information
■
“To Log Into the Service Processor Using the Network Management Port” on
page 55
■
SPARC Enterprise T5120 and T5220 Servers Administration Guide
▼
To Log Into the Service Processor Using the
Network Management Port
Note –
You must configure the service processor parameters shown in
the Service Processor Network Management Port” on page 52
before you can use the
network management port.
●
Open an SSH session and connect to the service processor by specifying its
network address.
->
set /SP/network commitpending=true
Set 'commitpending' to 'true'
%
ssh
root
@
xx.xxx.xx.x
...
Are you sure you want to continue connecting (yes/no)?
yes
...
Password:
password (nothing displayed)
Waiting for daemons to initialize...
Daemons ready
Integrated Lights Out Manager
Version 2.0.0.0
Summary of Contents for SPARC Enterprise T5120
Page 1: ......
Page 2: ......
Page 6: ......
Page 22: ...xx SPARC Enterprise T5120 and T5220 Servers Installation Guide July 2009 ...
Page 64: ...42 SPARC Enterprise T5120 and T5220 Servers Installation Guide July 2009 ...
Page 88: ...66 SPARC Enterprise T5120 and T5220 Servers Installation Guide July 2009 ...
Page 120: ...98 SPARC Enterprise T5120 and T5220 Servers Installation Guide July 2009 ...
Page 128: ...106 SPARC Enterprise T5120 and T5220 Servers Installation Guide July 2009 ...
Page 132: ...110 SPARC Enterprise T5120 and T5220 Servers Installation Guide July 2009 ...
Page 133: ......
Page 134: ......