68
SPARC Enterprise T5120 and T5220 Servers Installation Guide • July 2009
▼
To Update the Firmware
1. Ensure that the ILOM service processor network management port is
configured.
This configuration is required to access the new flash image over the network. See
“To Configure the Service Processor Network Management Port” on page 52
2. Open an SSH session to connect to the service processor.
3. Verify that the host is powered off.
If the host is not powered off, type the
stop /SYS
command.
4. Verify that the
keyswitch_state
parameter is set to
normal
.
5. Type the
load
command.
The
load
command updates the service processor flash image and the host
firmware. The
load
command requires the following information:
■
IP address of a TFTP server on the network that can access the flash image
%
ssh
root
@
xx.xxx.xx.x
...
Are you sure you want to continue connecting (yes/no)?
yes
...
Password:
password (nothing displayed)
Waiting for daemons to initialize...
Daemons ready
Integrated Lights Out Manager
Version 2.0.0.0
Copyright 2007 Sun Microsystems, Inc. All rights reserved.
Use is subject to license terms.
->
->
stop /SYS
->
set /SYS keyswitch_state=normal
Summary of Contents for SPARC Enterprise T5120
Page 1: ......
Page 2: ......
Page 6: ......
Page 22: ...xx SPARC Enterprise T5120 and T5220 Servers Installation Guide July 2009 ...
Page 64: ...42 SPARC Enterprise T5120 and T5220 Servers Installation Guide July 2009 ...
Page 88: ...66 SPARC Enterprise T5120 and T5220 Servers Installation Guide July 2009 ...
Page 120: ...98 SPARC Enterprise T5120 and T5220 Servers Installation Guide July 2009 ...
Page 128: ...106 SPARC Enterprise T5120 and T5220 Servers Installation Guide July 2009 ...
Page 132: ...110 SPARC Enterprise T5120 and T5220 Servers Installation Guide July 2009 ...
Page 133: ......
Page 134: ......