New Information About Known Issues
This section describes issues that were discovered since the previous edition of these
product notes was published.
Hardware and Mechanical Issues
TABLE 1-1
Hardware and Mechanical Issues
CR ID
Description
Workaround
6581309
To use the XVR-300 as a console of the SPARC
Enterprise T5xx0, patch 137111-01 or later must
be applied.
If the patch is applied after the OBP variable has
been changed to use the XVR-300 as the console,
console output will revert to the default ILOM
console during the Solaris boot sequence.
To use the XVR-300 as a console, apply patch
137111-01 or later to the Solaris OS before
changing the OBP variable.
Alternatively, install the Solaris OS (or reinstall
it) with ILOM set as the console used, and then
apply the patch.
No GUI can be used during that time.
After the patch has been applied, the XVR-300
can be used as the console as soon as the OBP
variable is changed.
Asset ID written in the RFID tag