Appendix A
Fixed Issues
73
Workaround: After you insert the power cord, or after the ILOM reset complete, wait
for about 180 seconds and then power on the system.
Slot Number of Link Card Connected to PCI Box
Is Falsely Displayed (CR 6942238)
This issue is resolved by updating the system firmware to 7.2.10 or later.
When you mount a link card connected to PCI box and start the system, the slot
number is falsely displayed in the LEDs and FRU Status of the
prtdiag -v
command output.
Shown below is an event example in time of failure.
Configuration:
PCIE#0: void
PCIE#1: void
PCIE#2: void
PCIE#3: void
PCIE#4: void
PCIE#5: Link Card
The ILOM CLI interface output example:
LEDs and FRU Status in the
prtdiag -v
command output:
/SYS/MB/RISER0/PCIE3/LINK
Properties:
type = Link Card
fru_description = Copper Link Card
fru_manufacturer = Celestica
fru_version = 02_51
fru_part_number = 5017041
fru_serial_number = XP00DD
fault_state = OK
connection = none
clear_fault_action = (none)
#
prtdiag -v
...
LEDs:
------------------------------------------------------
Location LED State
------------------------------------------------------