108
SPARC Enterprise T5440 Server Service Manual • July 2009
c. Switch to the system console to view POST output.
Watch the POST output for possible fault messages. The following output is a
sign that POST did not detect any faults:
Note –
Depending on the configuration of ILOM POST variables and whether
POST-detected faults or not, the system might boot, or the system might remain at
the
ok
prompt. If the system is at the
ok
prompt, type
boot
.
d. Return the virtual keyswitch to Normal mode.
e. Switch to the system console and issue the Solaris OS
fmadm faulty
command.
No memory faults should be displayed.
If faults are reported, refer to the diagnostics flowchart in
for an approach to diagnose the fault.
4. Switch to the ILOM command shell.
5. Run the
show faulty
command.
■
If the fault was detected by the host and the fault information persists, the
output will be similar to the following example:
->
start /SYS/console
.
.
.
0:0:0>INFO:
0:0:0> POST Passed all devices.
0:0:0>POST: Return to VBSC.
0:0:0>Master set ACK for vbsc runpost command and spin...
->
set /SYS keyswitch_state=Normal
Set ‘ketswitch_state’ to ‘Normal’
#
fmadm faulty
->
show faulty
Target | Property | Value
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/CPU0/CMP0/BR0/CH1/D0
Summary of Contents for SPARC Enterprise T5440 Server
Page 1: ......
Page 2: ......
Page 6: ......
Page 26: ...xxiv SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 84: ...58 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 180: ...154 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 192: ...166 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 198: ...172 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 212: ...186 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 213: ......
Page 214: ......