162
SPARC Enterprise T5440 Server Service Manual • July 2009
shows how to enable all the FB-DIMMs on
MEM1.
▼
Reset the LDoms Guest Configuration
After reconfiguring the I/O and PCIe fabric, you must recreate your LDoms guest
configurations, as hardware resources that had been previously assigned to your
guests might no longer be available.
1. Power off the system.
2. In the ALOM compatibility shell, type:
3. Power on the system.
4. Recreate your LDoms guests using the remaining hardware resources.
System Bus Topology
FIGURE: System Bus Topology on page 163
describes the system bus topology for the
SPARC Enterprise T5440 server.
CODE EXAMPLE:
Using the
enablecomponent
command to enable all FB-DIMMs on
CMP1
sc>
enablecomponent /SYS/MB/MEM1/CMP1/BR0/CH0/D1
sc>
enablecomponent /SYS/MB/MEM1/CMP1/BR0/CH0/D2
sc>
enablecomponent /SYS/MB/MEM1/CMP1/BR0/CH0/D3
sc>
enablecomponent /SYS/MB/MEM1/CMP1/BR0/CH1/D1
sc>
enablecomponent /SYS/MB/MEM1/CMP1/BR0/CH1/D2
sc>
enablecomponent /SYS/MB/MEM1/CMP1/BR0/CH1/D3
sc>
enablecomponent /SYS/MB/MEM1/CMP1/BR1/CH0/D1
sc>
enablecomponent /SYS/MB/MEM1/CMP1/BR1/CH0/D2
sc>
enablecomponent /SYS/MB/MEM1/CMP1/BR1/CH0/D3
sc>
enablecomponent /SYS/MB/MEM1/CMP1/BR1/CH1/D1
sc>
enablecomponent /SYS/MB/MEM1/CMP1/BR1/CH1/D2
sc>
enablecomponent /SYS/MB/MEM1/CMP1/BR1/CH1/D3
sc>
bootmode config="factory-default"
Summary of Contents for SPARC Enterprise T5440 Server
Page 1: ......
Page 2: ......
Page 6: ......
Page 26: ...xxiv SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 84: ...58 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 180: ...154 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 192: ...166 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 198: ...172 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 212: ...186 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 213: ......
Page 214: ......