28
SPARC Enterprise T5440 Server Service Manual • July 2009
2. Use the ILOM commands to change the POST parameters.
Refer to
TABLE: System Faults and Fault LED States on page 31
for a list of ILOM
POST parameters and their values.
The
set /SYS keyswitch_state
command sets the virtual keyswitch
parameter. For example:
To change individual POST parameters, you must first set the
keyswitch_state
parameter to
normal
. For example:
▼
Run POST in Maximum Mode
This procedure describes how to run POST when you want maximum testing, as in
the case when you are troubleshooting a server, or verifying a hardware upgrade or
repair.
1. Access the ILOM prompt.
See
“Connecting to the Service Processor” on page 22
2. Set the virtual keyswitch to
diag
so that POST will run in service mode.
3. Reset the system so that POST runs.
There are several ways to initiate a reset.
CODE EXAMPLE: Initiating POST With
shows a reset using a power cycle command sequence.
For other methods, refer to the
SPARC Enterprise T5440 Server Administration Guide
.
Note –
The server takes about one minute to power off. Use the
show /HOST
command to determine when the host has been powered off. The console will display
status=Powered Off
->
set /SYS keyswitch_state=Diag
Set ‘keyswitch_state’ to ‘Diag’
->
set /SYS keyswitch_state=Normal
Set ‘ketswitch_state’ to ‘Normal’
->
set /HOST/diag property=Min
->
set /SYS/keyswitch_state=Diag
Set ‘keyswitch_state’ to ‘Diag’
Summary of Contents for SPARC Enterprise T5440 Server
Page 1: ......
Page 2: ......
Page 6: ......
Page 26: ...xxiv SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 84: ...58 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 180: ...154 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 192: ...166 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 198: ...172 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 212: ...186 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 213: ......
Page 214: ......