Managing Faults
33
■
Environmental or configuration faults
– System configuration faults. Or
temperature or voltage problems that might be caused by faulty FRUs (power
supplies, fans, or blower), or by room temperature or blocked air flow to the
server.
■
POST-detected faults
– Faults on devices detected by the POST diagnostics.
■
PSH-detected faults
– Faults detected by the Solaris Predictive Self-Healing (PSH)
technology.
■
External I/O Expansion Unit faults
– Faults detected in the optional External I/O
Expansion Unit.
Use the
show faulty
command for the following reasons:
■
To see if any faults have been diagnosed in the system.
■
To verify that the replacement of a FRU has cleared the fault and not generated
any additional faults.
Related Information
■
“Diagnostic Flowchart” on page 11
■
“Detecting Faults Using LEDs” on page 30
■
“ILOM-to-ALOM CMT Command Reference” on page 53
■
SPARC Enterprise T5440 Server Installation and Setup Guide
■
SPARC Enterprise T5440 Server Administration Guide
■
Integrated Lights Out Manager 3.0 Supplement for SPARC Enterprise T5440 Server
▼
Detect Faults Using the ILOM
show faulty
Command
●
At the
->
prompt, type the
show faulty
command.
The following
show faulty
command examples show the different kinds of
output from the
show faulty
command:
■
Example of the
show faulty
command when no faults are present:
->
show faulty
Target | Property | Value
--------------------+------------------------+-------------------------------
-----------------------------------------------------------------------------
Summary of Contents for SPARC Enterprise T5440 Server
Page 1: ......
Page 2: ......
Page 6: ......
Page 26: ...xxiv SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 84: ...58 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 180: ...154 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 192: ...166 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 198: ...172 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 212: ...186 SPARC Enterprise T5440 Server Service Manual July 2009 ...
Page 213: ......
Page 214: ......