The
Information
area
at
the
top
of
the
screen
turns
clear,
and
the
location
LED
of
the
part
requiring
maintenance
is
turned
off.
4.1.3
Precaution
on
Maintenance
Mode
If
a
failure
occurs
in
the
FANU,
maintenance
mode
cannot
be
set
for
the
CMU.
Also,
the
following
message
will
appear.
Figure
4.2
Error
Message
(at
FANU
Failure)
For
this
reason,
replace
the
FANU
first.
4.2
Updating
HCP
Firmware
To
update
HCP
firmware,
configure
settings
from
the
Web
GUI.
-
Selecting
and
registering
HCP
firmware
from
[Firmware
Update]
For
the
setting
procedure,
see
For
the
precaution
during
updates,
see
"
-
Applying
HCP
firmware
For
the
setting
procedure,
see
."
Remarks
Before
selecting
[Firmware
Update],
confirm
that
[Running
Status]
is
"Stop"
for
all
nodes.
4.2.1
Registering
HCP
Firmware
1.
Log
in
to
the
Web
GUI.
2.
Select
[Firmware
Update]
in
[Maintenance]
from
the
menu.
The
[Firmware
Update]
screen
appears
Chapter
4
Basic
Software
Procedures
C120-0090-04EN
4.2
Updating
HCP
Firmware
25