4 Configuring the installation
All kits must be connected in of the house as shown on
the figures (
.
"
optional DHW kit
DHW tank control (with electrical back-up) requires
the use of the DHW kit.
Warning : The DHW tank must be fitted with an electric
back-up, particularly for anti-legionella cycles.
"
optional boiler connection kit
The connection of an oil or gas boiler to the heat pump
requires the installation of the boiler connection kit.
"
Swimming pool kit option
Please refer to the instructions supplied with the
swimming pool kit.
Configuration
(Parameter 5700)
Type of installation
Page
Pre-setting 1
1 heating circuit.
Pre-setting 2
1 heating circuit and DHW tank.
Pre-setting 3
Do not use for monobloc heat pump. Reserved only for 2 circuits installation.
Pre-setting 4
Pre-setting 5
Boiler connection and 1 heating circuit.
Pre-setting 6
Do not use for monobloc heat pump. Reserved only for 2 circuits installation.
Pre-setting 7
Boiler connection, 1 heating circuit and DHW tank.
Pre-setting 8
Do not use for monobloc heat pump. Reserved only for 2 circuits installation.
Pre-setting 9
Do not use for monobloc heat pump. Reserved only for heat pump 2 services.
Pre-setting 10
Pre-setting 11
Pre-setting 12
"
Please consult us regarding any other installation configuration
Installation and operating manual "1395 - EN"
Control Box
- 28 -