background image

FY-250ZDY8

FY-350ZDY8
FY-500ZDY8

FY-650ZDY8

UTZ-BD025C
UTZ-BD035C
UTZ-BD050C

UTZ-BD100C

UTZ-BD025C
UTZ-BD035C
UTZ-BD050C

FY-800ZDY8

FY-01KZDY8A

UTZ-BD080C

UTZ-BD080C
UTZ-BD100C

A

1

7

11

2

H

H

I

5

6

10

9

G

P

K
L

M

C

C

4-13×30 Oval hole

F

G

4

3

B

J

N

E

5

6

2222

1

H

H

I

A

E

8

8

9

10

G

G

F

11

7

4

3

C

C

B

J

P

N

L

M

K

8

Model No.UTZ-BD035C and UTZ-BD050C  

have two Heat Exchange Elements.

have different fan and motor locations.

Model No.UTZ-BD100C  has four Heat  

Exchange Elements.

Note2)

Note1)

Note1)

414

1050

70

978

112

580

470

182

317

70

1018

132

1090

640

470

182

317

Number

Name

Note

Quantity

1

Frame

1

2

Adapter

4

3

Terminal

1

4

Inspection Cover

1

5

Fan

2

6

Motor

Note2)

2

7

Heat Exchange element

Note1)

1

8

Filter

2

9

Damper

1

10

Damper Motor

1

11

Ceiling Suspension Fixture

4

12

Electrical Equipment Box

1

13

Energy Recovery Ventilator Remocon

1

Number

Name

Note

Quantity

1

Frame

1

2

Adapter

4

3

Terminal

1

4

Inspection Cover

1

5

Fan

2

6

Motor

2

7

Heat Exchange element

Note1)

3

8

Filter

2

9

Damper

1

10

Damper Motor

1

11

Ceiling Suspension Fixture

4

12

Electrical Equipment Box

1

13

Energy Recovery Ventilator Remocon

1

UTZ-BD025C

UTZ-BD035C

UTZ-BD050C

UTZ-BD080C

UTZ-BD100C

Model No.UTZ-BD035C and UTZ-BD050C  

Summary of Contents for UTZ-BD025C

Page 1: ...UTZ BD025C UTZ BD035C UTZ BD050C UTZ BD080C UTZ BD100C ...

Page 2: ...persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involves Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Make sure to disconnect the power plug before c...

Page 3: ......

Page 4: ...SA OA EA RA SA OA 600 A Model UTZ BD035C and UTZ BD050C have two Heat Exchange Elements kg kg 370 UTZ BD025C UTZ BD080C UTZ BD100C UTZ BD080C UTZ BD100C UTZ BD035C UTZ BD050C UTZ BD025C UTZ BD035C UTZ BD050C UTZ BD100C ...

Page 5: ... Cable for supply cord VVF cable with Φ1 6 or Φ2 Cable for connecting main unit and remote controller 300V 500V 60227IEC10 hard wire Cross section area for each core wire is 1 5mm2 ...

Page 6: ...0 70 978 112 580 470 182 317 70 1018 132 1090 640 470 182 317 Number Name Note Quantity 1 Frame 1 2 Adapter 4 3 Terminal 1 4 Inspection Cover 1 5 Fan 2 6 Motor Note2 2 7 Heat Exchange element Note1 1 8 Filter 2 9 Damper 1 10 Damper Motor 1 11 Ceiling Suspension Fixture 4 12 Electrical Equipment Box 1 13 Energy RecoveryVentilator Remocon 1 Number Name Note Quantity 1 Frame 1 2 Adapter 4 3 Terminal ...

Page 7: ...screws fixing the cover of the electrical components box open the cover and connect wires cables correctly Secure the cable drawn from the terminal board firmly with the cable holder If a large volume of air is requierd or a long duct is used switch the wire connection from Low to Extra high according to the following steps Remove two screws securing the cover of the electrical components box and ...

Page 8: ...UTZ BD080C UTZ BD100C 10 0 10 0 UTZ BD035C UTZ BD050C 3 5 6 0 Lo Hi Lo Hi Relay 4 ...

Page 9: ...esponding to each model number Using an inappropriate power supply may cause the motor to burn out Grounding work must be based on Class D as defined in Technical Standards for Electrical Equipment After wire connections are completed check the connection again before turning the power on Model No UTZ BD080C UTZ BD100C two Fan Motors are stopped during an operation of the damper ...

Page 10: ...Printed in China Gedruckt in China Imprimé en Chine Impreso en China Stampato in Cina Impresso na China 25ZDY8RFG0854 P0917 0 Pursuant to at the directive 2014 30 EU article 9 2 ...

Reviews: