background image

Safety

 

and

 

Installation

 

Guide

Safety

 

and

 

Installation

 

Guide

P3NK-3612-01EN

Safety and Installation Guide

Introductory

Summary of Contents for XG0224

Page 1: ...Safety and Installation Guide Safety and Installation Guide P3NK 3612 01EN Safety and Installation Guide Introductory ...

Page 2: ...bout Warning Descriptions 4 1 2 Notes on Rack Mounting and Connecting a Powerstrip 7 Chapter 2 Installation 8 2 1 Requirements for Installation Environment 9 2 1 1 Installation Requirements 9 2 2 Installation 11 2 2 1 Installation of the Switch 11 2 2 2 Installation of Extension Card 12 ...

Page 3: ...Chapter 1 Safety Precautions This chapter describes how to Safety Precautions 1 1 About Warning Descriptions 4 1 2 Notes on Rack Mounting and Connecting a Powerstrip 7 ...

Page 4: ...s that improper use can cause severe damage to person resulting in serious injury or death Indicates that improper use can cause light or moderate injury In addition this symbol indicates a chance of damage to this device and other connected equipment Symbols Definitions The symbol in form indicates a warning or cautionary note Specific information is shown inside or next to the symbol The symbol ...

Page 5: ...e to follow this may result in electric shock If you notice abnormal conditions such as overheating smoke emission or odor stop using this device immediately and pull unplug the power cable from the socket Make sure that abnormal conditions such as smoke no longer exist and contact our engineer or an engineer certified by Fujitsu Continuing to use the device in this condition may result in electri...

Page 6: ... microwave oven and other equipments that emit strong magnetic field Failure to follow this may cause system failure Ensure enough space for the vent of this device and cables If you use two of the same type of device in parallel you need to have service areas for each Failure to follow this may cause cable failures Make sure to unplug the power cable when transporting this device Failure to follo...

Page 7: ...g Check the power supply capability of the installation location If you connect the power cable of this device to a powerstrip a large amount of current leakage can occur through the ground line of the strip Make sure to establish a ground connection before connecting to the power If the power cable is not directly connected to the distribution board you must use a powerstip with industrial use pl...

Page 8: ...This chapter describes how to install the switch 2 1 Requirements for Installation Environment 9 2 1 1 Installation Requirements 9 2 2 Installation 11 2 2 1 Installation of the Switch 11 2 2 2 Installation of Extension Card 12 ...

Page 9: ... conditions 2 1 1 Installation Requirements Caution Install the product under the following conditions Using the product outside the required environment may cause failure of the product Temperature and Humidity Requirements Power Requirements Temperature degrees C Humidity RH Operation 0 to 40 15 to 85 Non operation 0 to 50 8 to 90 Item Requirements Voltage AC90V 264V Frequency 50Hz 60Hz 2 4 Grou...

Page 10: ...Check Result Nothing is put on the switch Vents are not obstructed The switch is not located on the table or not stuck on another switch The switch is not located under direct sunshine near heating appliance under high humidity or in a dusty area The switch is not located on unstable places where vibrating or tilting About Warning Descriptions has been thoroughly read ...

Page 11: ...ing temperature can be maintained properly for the switch Reserve certain space for air cooling in accordance with the cooling structure of the switch Reserve certain space for air cooling in accordance with the cooling structure of the switch Check if power supply capacity Rated Current is sufficient from the power supply equipment such as power strip service outlet from other devices or rack Whe...

Page 12: ...row of the rack may interfere with the power cable of the switch from being properly installed In that case plug the power cable to the switch before install it in the rack 2 2 2 Installation of Extension Card The extension cards can be installed to the switch as optional Below describes how to install each extension card Installation of SFP Extension Card CX4 Extension Card Below describes the ca...

Page 13: ...FP card plug in the SFP module Removing SFP Extension Card CX4 Extension Card 1 Turn off the power of the switch Caution If the extension card is removed when the power is on the Check LED will light up and the switch will go into trouble state 2 Loosen the screws on the extension slot and remove the extension card 3 Put the cover panel on the extension slot and fix it on the switch with the screw...

Page 14: ...sed without prior notice Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual No part of this manual may be reproduced in any form without the prior written permission of Fujitsu Manuals with missing or wrongly collated pages will be replaced free of charge ...