XG700 User's Guide
201/266
All Rights Reserved, Copyright (C) PFU LIMITED 2005-2006
5.17.3 rmon alarm
Function
Sets RMON alarms. Up to 30 entries can be set.
Use the no form to delete the information you have set.
Prompt
xg(config)#
Command syntax
rmon alarm INDEX VARIABLE interval VALUE {absolute | delta}
rising-threshold VALUE [EVENT-NUM] falling-threshold VALUE [EVENT-NUM]
[owner OWNERNAME]
no rmon alarm INDEX
Parameter
INDEX
Specifies an entry index of the RMON alarm within the range of 1 to 65535.
VARIABLE
Specifies an OID of the MIB object to be monitored.
A name such as “ifEntry.10.2” cannot be set for the OID. The OID must be a string of decimal integers separated by a
dot (.) from each other. An example of “1.3.6.1.2.1.1.2.2.1.10.2”.
interval VALUE
Specifies an interval (in seconds) for threshold check of the MIB to be monitored. The VALUE can be an integer of 2 to
65535.
{absolute | delta}
Specifies a threshold evaluation method as follows.
−
absolute
The value obtained from the MIB is evaluated as the absolute value.
−
delta
A difference between the value obtained from the previous MIB and the value obtained from the current MIB is
evaluated.
rising-threshold VALUE [EVENT-NUM]
The VALUE specifies the threshold upper limit or the “rising threshold.”
The EVENT-NUM specifies an index of the event to be executed if the rising threshold is exceeded.
falling-threshold VALUE [EVENT-NUM]
The VALUE specifies the threshold lower limit or the “falling threshold.”
The EVENT-NUM specifies an index of the event to be executed if the falling threshold is exceeded.
owner OWNERNAME
Specifies an owner name of the entry using up to 127 alphanumeric characters.
If omitted, no owner name is set.
Command type
Configuration command
Default
None
Message
% RMON alarm can register up to 30
Explanation
No more setup is allowed as the RMON alarm group data has reached the registration limit.
Solution
Delete unnecessary RMON alarm groups, and reissue the command.
% RMON alarm %1$ is not set.
Explanation
You have attempted to delete a non-existing RMON alarm group.
[[Inserted string]]%1$: Specified index
Solution
Review the specified index, and reissue the command.
% OWNERNAME is too long.
Explanation
The owner name has exceeded the limit length.
Solution
Review the owner name length and reissue the command.
% OID cannot be used.
Explanation
Unusable character has been specified for the OID.
Solution
Review the specified OID, and reissue the command.
% OWNERNAME cannot be used.
Explanation
Unusable character has been specified for the "owner".
Solution
Review the specified “owner”, and reissue the command.