XG700 User's Guide
204/266
All Rights Reserved, Copyright (C) PFU LIMITED 2005-2006
5.18 System Operation Display Commands
This section explains about the command to display the system operation status.
5.18.1 show system status
Function
Displays the hardware operation status.
For the explanation and actions taken of each item, see the "
Verifying Hardware Status
".
Prompt
xg> or xg#
Command syntax
show system status
Command type
Operation management command
Output format
xg11# show system status
System Status Information 2005/08/22-12:16:19
==============================================
[Temperature]
Internal : good
Inlet
: good
[Power Supply]
PWR-1
Mount : good
Output Power
:
PWR-2
Mount : good
Output Power
: good
[Voltage]
Voltage : good
[Fan]
Rear Fan-1
: good (normal-speed)
Rear Fan-2
: good (high-speed)
PWR-1 Fan
: good (normal-speed)
PWR-2 Fan : good (normal-speed)
Temperature
Displays the temperature in the system hardware.
−
Internal
Internal temperature sensor
−
Inlet
Inlet temperature sensor
Power Supply
Displays the operation status of power supply
PWR-1
Displays the operation status of power supply 1.
−
Mount
Displays the mounting status of the power supply.
−
Output Power
Displays the power output status.
PWR-2
Displays the operation status of power supply 2. The display items are the same as for power supply 1.
Voltage
Displays the voltage status. If all the voltages are normal detailed, information is not displayed.
−
VDP
Displays the VDP voltage status.
−
VDE
Displays the VDE voltage status.
−
VDR
Displays the VDR voltage status.
−
VDD
Displays the VDD voltage status.
−
VDN
Displays the VDN voltage status.
−
3.3V Stby
Displays the 3.3V voltage status.
−
+12V
Displays the 12V voltage status.