XG700 User's Guide
219/266
All Rights Reserved, Copyright (C) PFU LIMITED 2005-2006
The following table provides descriptions of items displayed when the "show system status" command is entered and a
response for each error message.
Item
Item displayed
Message explanation/Solution
Temperature (inside the chassis)
Displays the temperature inside the chassis.
Internal (internal temperature sensor)
good
The temperature is within normal operating range.
Internal Temperature is out of range. (xx)
A temperature error has been detected. Reexamine the following
points concerning the set up of XG700.
−
Check that the air vent is not blocked.
−
Check that the temperature of the set up location is
within the limits set out by the operation guarantee.
If the same message is displayed after re-examining the set up of
the XG700, contact your XG700 sales representative.
Inlet (inlet temperature sensor)
good
The temperature is within normal operating range.
Inlet Temperature is out of range. (xx)
A temperature error has been detected. Reexamine the following
points concerning the set up of XG700.
−
Check that the air vent is not blocked.
−
Check that the temperature of the set up location is
within the limits set out by the operation guarantee.
If the same message is displayed after re-examining the set up of
the XG700, contact your XG700 sales representative.
Power Supply PWR#-1 (status of power supply unit 1)
Display the status of power supply unit 1.
Mount (installation of power supply unit)
good
The power supply unit is properly installed.
Removed
The power supply unit has been removed. If this message appears
with the power supply unit installed, check that the unit is properly
installed.
Output Power (power supply outputs)
good
The output power is within normal operating range.
PWR-1 ALARM Detected.
A power supply error has been detected or no power is reaching the
power supply unit. Check for AC inputs. If this message appears
after the checking for AC inputs, replace the power supply.
Power Supply PWR#-2 (status of power supply unit 2)
Mount (installation of power supply unit)
Output Power (power supply outputs)
Displays the status of power supply unit 2.The messages and
actions to take are the same as those described for power supply
unit 1.
Voltage (voltage status)
Displays status of fans.
Voltage
good
The voltage is within normal operating range.
VDP: Out of range. (xx)
A VDP voltage error has been detected. Contact your XG700 sales
representative.
VDE: Out of range. (xx)
A VDE voltage error has been detected. Contact your XG700 sales
representative.
VDR: Out of range. (xx)
A VDR voltage error has been detected. Contact your XG700 sales
representative.
VDD: Out of range. (xx)
A VDD voltage error has been detected. Contact your XG700 sales
representative.
VDN: Out of range. (xx)
A VDN voltage error has been detected. Contact your XG700 sales
representative.
3.3V Main: Out of range. (xx)
A 3.3V power supply error has been detected. Contact your XG700
sales representative.
12V Main: Out of range. (xx)
A 12V power supply error has been detected. Contact your XG700
sales representative.