XG700 User's Guide
227/266
All Rights Reserved, Copyright (C) PFU LIMITED 2005-2006
6.4.2 Procedure for Extracting Maintenance Information when a System
Loop has Occurred
This section describes the procedures for extracting maintenance information when a system loop has occurred.
A system loop has occurred.
If a CLI command entry is not accepted for an extended period of time, a system loop may have occurred.
Press the "dump" switch on the XG700's front panel.
The maintenance information is automatically saved when the "dump" switch is pressed, and then the system restarts.
Reporting system logs on dump outputs/Reporting traps
After the system retorts, a system log is issued to indicate that a forced system dump was generated. Configuring an
SNMP trap in advance causes a trap indicating the occurrence of a system failure to be reported to a system
administrator.
Viewing maintenance information history
Using the "
show maintenance
" command, check that the maintenance information has been saved.
xg# show maintenance
Maintenance Information 2005/08/22-15:55:20
==================================================
NO Type Occurred Time
--- -------------------------- -------------------
1 system dump(Dump switch) 2005/08/22-18:21:23
==================================================
The maintenance information that was saved by the "dump" switch is represented by "system dump(Dump switch)" in
"Type".
Extracting maintenance information
Using the "
tftp put-maintenance
" command, forward the maintenance information to a TFTP server machine.
Contact your XG700 sales representative.
6.4.3 Procedure for Extracting Maintenance Information when an
XG700 Malfunction Occurs
This section describes the procedures for extracting maintenance information when an XG700 malfunction has occurred.
A malfunction has occurred.
When a function configured for the XG700 fails to operate properly, the maintenance information can be extracted
using the command.
Using the "
save maintenance
" command, save the maintenance information.
Viewing maintenance information history
Using the "
show maintenance
" command, check that the maintenance information has been saved.
xg# show maintenance
Maintenance Information 2005/08/22-15:55:20
==================================================
NO Type Occurred Time
--- -------------------------- -------------------
1 system state 2005/08/22-20:58:14
==================================================
The maintenance information that was saved by the "
save maintenance
" command is represented by "system state" in
"Type".
Extracting maintenance information
Using the "
tftp put-maintenance
" command, forward the maintenance information to a TFTP server.
Contact your XG700 sales representative.