XG700 User's Guide
75/266
All Rights Reserved, Copyright (C) PFU LIMITED 2005-2006
% OFFSET '%1$' is invalid
Explanation
The specification of OFFSET is incorrect.
[[Inserted string]]%2$: incorrect parameter value is displayed.
Solution
Correct the error of the parameter, and execute it again.
% Parameter '%1$' is too long
Explanation
Specification of the parameter is too long.
[[Inserted string]]%1$: incorrect parameter value is displayed.
Solution
Correct the error of the parameter, and execute it again.
% DATE '%1$' is too long
Explanation
Specification of the date is too long.
[[Inserted string]]%1$: incorrect parameter value is displayed.
Solution
Correct the error of the parameter, and execute it again.
% Type of start-day and end-day is inconsistency
Explanation
Different forms of dates are specified for the start date and end date to the parameters of the Day Light Saving
Time.
Solution
Make the forms of dates of the start date and end date of the Day Light Saving Time (Mm.w.d/ Jn/ n) consistent,
and execute it again.
Note
The setting will be valid after restarting the system.
Use the "show system information" command to confirm the settings.
The setting will not be included in the configuration information. Therefore, even if the configuration information was
restored at another device, the setting of the timezone will be invalid.
Example
Set the Day Light Saving Time (from 2:00 on Sunday of the first week in April to 02:00 on Sunday of the fifth week in October,
with the time difference of an hour).
xg# date summer-time M4.1.0/0200 M10.5.0/0200 0100