TRUE Grade Mode
●
Press the red “
G
” button once and the FRE-203XT will enter “True Grade”
mode.
●
The X axis indicator will begin fl ashing to indicate it is ready for a % to be
input into the X axis.
●
Please see page
23
for the Gradient Conversion Chart.
●
Using the keypad or remote control, press either the Increase / Decrease
Slope Angle button until the desired % is displayed on screen.
●
When complete, press the X & Y Axis Selector button once and repeat the
process to enter a % in the Y axis. If you only want to enter a value in the X
axis simply leave Y set at
0.00
%.
●
To fi nally confi rm the % entered in either the X, Y or both axis, press the X
& Y Axis Selector button once more
.
●
The laser prism will then tilt to the correct angle and then begin rotating at
600rpm.
●
To return to Auto level, the red “
G
” button once. The laser prism will stop
rotating and will then adjust to true level. It will then automatically restart
rotating, auto levelled.
USING THE LASER (CONTINUED 3)
18
In combination with:
X & Y Axis Selector
True Grade Mode
Increase Slope Angle
Decrease Slope Angle