background image

Remote Control...

Fit the supplied 2pc x AA alkaline batteries, taking care with correct polarity.
The Remote’s keypad can set the following functions:
1. Rotating speed in increments; slow for Indoors, fast (max) for Outdoors
2. Scan angles & position around the room.
3. ADS (see above)
4. Auto / Manual (grade) setting via the red "G" button.
5. X/Y button to set required grade axis, then +/- button to adjust the % 
value.

In fact, it is often better to use the Remote Control rather than the 
instrument's keypad, because then you do not disturb the laser's sensitive 
mechanism.

Detector...

Fit the supplied 9V battery, polarity marked. Power up via red ON/OFF button.
The middle button switches the sounder ON or OFF, & volume - if required
The right hand button sets coarse (+/-2mm) or fine (+/-1mm) red pick-up 
window resolution.
A rear LCD repeats the main front display.
Note case markings & setting notches.
You can use the detector with or without its staff mounting bracket.

Detector Procedure

 – face towards rotating laser & "find" rotating laser 

beam via the pick-up window.
If the sun is low in the sky & shining into the red window, shield it with a 

5

Summary of Contents for FRE-207

Page 1: ...t requires calibration or repair then please contact our Service Dept on tel 01246 269 777 or fax 01246 260 007 We would be pleased to help Power source This is a special battery pack located in the base of the laser Remove refit via a central screw finger tight no tools required It contains 4pc x sealed for life Ni MH type C 4000mAh 1 2V cells Please note that this battery pack can be charged eit...

Page 2: ...rging the batteries fully overnight A Spare Battery holder is also included to be used as a back up power source Four type C 1 5V Alkaline batteries can be used instead or in an emergency but do NOT attempt to recharge them otherwise serious damage will occur Positioning the Laser Mount the FRE 207 on a generally level firm surface or 5 8 threaded Tripod To operate correctly this surface must be w...

Page 3: ...o manual to over ride the level sensors and then it is very easy for the User to set a grade incline slope in the X axis only Y axis only or both together The max settable slope range is 10 00 ie 1 10 For X Y alignment please see the white markings on the TOP of the laser body where an arrow points in the direction of the axis being set Setting a single axis slope This sets a grade in the X axis P...

Page 4: ...ally restart self levelled Setting both X Y axis slope dual grade Proceed as above but enter values for both X Y Automatic Drift System ADS Operated via bottom right hand yellow button showing a picture of a tilted instrument and repeated on the Remote Control Once the FRE 207 is ON and rotating in the auto self levelled mode the automatic drift system can be activated Press the button TILT wil be...

Page 5: ...rather than the instrument s keypad because then you do not disturb the laser s sensitive mechanism Detector Fit the supplied 9V battery polarity marked Power up via red ON OFF button The middle button switches the sounder ON or OFF volume if required The right hand button sets coarse 2mm or fine 1mm red pick up window resolution A rear LCD repeats the main front display Note case markings setting...

Page 6: ...s is an accurate measuring device so to give good service look after it Prevent the FRE 207 from receiving severe knocks bangs or vibration Store the laser its accessories in the supplied carry case If wet dry before storing keep in storage temperatures between 5 30 deg C Remove all batteries before long term storage to prevent internal damage Key Specifications Laser accuracy 3mm 30m Operating ra...

Page 7: ...he various Trades are also available on request Eg Tripods staffs wall brackets screeding poles etc Please contact us P R Engineering Ltd Unit 35 Bridge Business Centre Beresford Way CHESTERFIELD S41 9FG England Tel 01246 269777 Fax 01246 260007 sales laser level co uk www laser level co uk 7 ...

Reviews: