C17AK0006 REV.1SLIMBOX-V, INDOOR/OUTDOOR ENCLOSURE-4F
ISSUE DATE 8/9/2017
pg. 6
5.
When field terminating connectors utilize the vendor specific instructions for direct
termination, mechanical or splice on connectors for 900 um buffered fiber.
6.
When doing a mid-span cable the cable enters on the left side is wrapped two times and
exits on the far right hand side drop port (only three drops are allowed in the mid-span
entry). The EZ Cable Clii Shark Tooth Anchors. Place the anchors close to the enclosure
to assist in strain relief. The Indoor/Outdoor cable is smaller than the bracket and can be
held in place with a cable tie included in the accessory package. When doing a mid-span
the cable exits from one of the drop ports. The exit end of the cable is clamped into the
plastic drop grip at the base of the enclosure (see the photo below).
7.
When the enclosure is pre-terminated the cable will already be installed and up-jacketed
and you can move to step 8 for drop installation.
Drop Cable Clamp: Remove
the two screws with a
Phillips head screwdriver
and place the drops in the
drop holder. Replace the
top part of the clamp and