Cleaning - Troubleshooting
EN
Green and
Yellow to Earth
Blue to
Neutral
13 amp Fuse
Brown
to Live
Cord Clamp
R
V
CLEANING
Before starting any cleaning, disconnect the
appliance from the mains electricity supply.
The protections (wire grill, covers) must not be
removed by unqualified personnel: do not use the
appliance if the protections have been removed.
WHEN CLEANING THE INTERNAL PLASTIC PARTS AND
THE DOOR GASKET:
do not use abrasives or detergents of any kind.
- Use a warm solution of bicarbonate of soda (two
spoonfuls in two litres of water).
CLEANING THE CONDENSER
- This should be carried out at least twice a year.
- Clean using a domestic vacuum cleaner or a brush.
A dirty condenser will have a negative effect on the
appliance and reduce its performance.
FOR PROLONGED ABSENCES
- if the appliance is to be left unused for a long period
of time, e.g. holidays, it must be unplugged, emptied,
cleaned and dried. The door must be left open to
prevent the formation of bad smells.
CLEANING THE WATER DRAIN
When cleaning the condenser, check that the rear drain
pipe R is not blocked.
- Remove drain pipe R from the container V and if
necessary clean it.
POWER SUPPLY CABLE
- Periodically inspect the power cable to check its
condition.
- If the cable is damaged, do not use the appliance and
do not attempt any repairs. Call a qualified technician
to replace the faulty cable.
ELECTRICAL CONNECTION
Check that the mains voltage complies with that indicated on
the rating plate located on the bottom left of the compartment.
If the mains socket does not have an earth connection or if
the plug is not suitable for the mains supply system, refer to
a qualified electrician. Do not use adapters or extension leads,
as these may overheat and burn.
WARNING: THIS APPLIANCE MUST BE EARTHED
If the appliance has been fitted with a non-rewirable plug of
the incorrect type for the mains socket, cut off the plug and fit
a new one. The removed plug must be thrown away. Inserting
an unsuitable plug into a 13 Amp socket is likely to cause an
electrical hazard. When a non rewirable plug or rewirable 13
Amp (BS1363) plug is used, it must be fitted with a 15 Amp
A.S.T.A. approved (BS1362) fuse. If any other type of plug is
used it must be wired as follows. Connect the GREEN & YEL-
LOW wire to the earth terminal marked with the letter “E” or
earth symbol, or coloured green or green & yellow. Connect
the BLUE wire to the neutral terminal marked with the letter
“N” or coloured black. Connect the BROWN coloured wire to
the live terminal marked with the letter “L” or coloured red.