Error 

displayed

Problem type

Possible cause

Possible solution

b

Single burner locked

No gas

Restore the gas and unlock the 

burners

Ionization elect rode dirty or not hit by the flame

Clean or reposition the 

electrode and unlock the 

burners

The cook top is not grounded

Check the cables and unlock 

the burners

F

Parasite flame/flame detection 

circuit anomaly on the single 

burner

Ionization electrode wired incorrectly

Check the wiring

Failure at the circuit

Replace the device

Flt00

Main valve control circuit 

anomaly

Failure at the circuit

Replace the device

Flt01

Anomaly circuit voltage of 

reference

Failure at the circuit

Replace the device

Flt02

Watchdog circuit anomaly

Failure at the circuit

Replace the device

Flt03

Microcontroller door anomaly

Failure at the circuit

Replace the device

Flt04

Eeprom anomaly

Failure at the circuit

Replace the device

Flt05

Pilot valve circuit anomaly

Failure at the circuit

Replace the device

Flt06

Limit of 5 unlocks in 15 

minutes exceeded

The burners have been unlocked 5 times in 15 

minutes

Wait 15 minutes before 

unlocking the burners

Flt08

Power supply circuit anomaly

Failure at the circuit

Replace the device

Flt09

Generic anomaly

Power was cut to the device when another type 

of failure had occurred previously

Unlock the burners

Resonator anomaly

Failure at the circuit

Replace the device

Flt0A

All burners locked

No gas

Restore the gas and unlock the 

burners

Ionization electrodes dirty or not hit by the flame

Clean or reposition the 

electrodes and unlock the 

burners

The cook top is not grounded

Check the cables and unlock 

the burners

Gas is leaking from one valve that caused the 

unwanted lighting of a second burner while the 

first was being lit.

This problem is caused by flame in the second 

burner for more than 10 seconds.

Replace the defective valve

Flt0[

Communication errors in the 

control logic

Failure at the circuit

Replace the device

Flt0E

Error in the control of the 

keypad

A mechanical deformation could have 

compromised the support of the keypad by the 

glass

Wait several seconds for the 

keypad to recalibrate. If the 

error persists, turn the power 

off and on. If the error still 

persists, replace the device.

Ft1E

Control panel hardware error

Circuit failure

Check that the control panel 

board is correctly inserted into the 

connector. Replace the device

Ft2E

Control panel hardware error

Circuit failure

Check that the control panel 

board is correctly inserted into the 

connector. Replace the device

Summary of Contents for DG

Page 1: ...Domino Gas Model No DG and DGW www fulgor com au cooking collection Instructions for use and warranty details ...

Page 2: ...2 ...

Page 3: ... new appliance Correct installation will avoid delays and unnecessary service call costs Once installation is complete please read this entire instruction manual carefully and get to know the controls and the features of your new Fulgor Milano appliance Again congratulations and thank you for choosing Fulgor Milano Congratulations on the purchase of your new Fulgor Milano appliance ...

Page 4: ... CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FORTHEIR SAFETY CHILDREN SHOULD BE SUPERVISED TO ENSURETHATTHEY DO NOT PLAYWITHTHE APPLIANCE Dear customer We thank you and congratulate you on your choice This new carefully designed product manufactured with the highest quality materials...

Page 5: ...r to be timed The word Time will disappear and be replaced by the indication 0 00 The burner selected is identified by the relative Led The flashing digit to the left of the dot indicates the hours while those to the right indicate the minutes By pressing the or keys of the burner selected it is possible to increase or decrease the operating hours from 0 to 9 Keeping the or keys pressed the change...

Page 6: ...e hob by pressing the ON OFF button It is not possible to release a locked burner when the control panel lock is active It will be therefore necessary to release the control panel before activating the burner release procedure Releasing the control panel The control panel is released by pressing the KL and A keys for at least 2 seconds The control panel is released when the flame level points on t...

Page 7: ...A DISPLAY B PUNTI DECIMALI DISPLAY TIMER A A B B LED B LED A PT KL ON OFF DISPLAY A DISPLAY B PUNTI DECIMALI DISPLAY TIMER A A B B LED B LED A PT KL ON OFF Fig 1 Fig 2 Mod DG Mod DGW DECIMAL POINTS DECIMAL POINTS ...

Page 8: ...cts bleach etc avoid leaving acid or alkaline substances on the working area vinegar salt lemonjuice etc the wall baffle and the small covers mobile parts of the burner must be washed frequently with boiling water and detergent taking care to remove every possible encrustation Dry carefully and check that none of the burner holes is fully or partially clogged e h t f o n o i t i d n o c f o e t a ...

Page 9: ...adclearances MeasurementA Sideclearances MeasurementB C Installation 5IJT BQQMJBODF JT OPU QSPWJEFE XJUI B DPNCVTUJPO QSPEVDU EJTDIBSHF U JT SFDPNNFOEFE UIBU JU CF JOTUBMMFE JO TV DJFOUMZ BFSBUFE QMBDFT JO UFSNT PG UIF MBXT JO GPSDF 5IF RVBOUJUZ PG BJS XIJDI JT OFDFTTBSZ GPS DPNCVTUJPO NVTU OPU CF CFMPX N I GPS FBDI L8 P QPXFS 4FF UBCMF PG CVSOFS QPXFS Positioning Fig 5 5IF DPPL UPQ JT EFTJHOFE UP...

Page 10: ...1 2 1 5 510 380 R 11 73 1 1 2 PUF 4FNJGJMPUP NPEFMT EP OPU OFFE UP CF MPXFSFE CZ NN 1 AUXILIARY 2 RAPID 381 1 0 511 1 0 360 1 0 490 1 0 R 1 2 1 5 380 510 R 11 73 1 1 1 DUAL PUF 4FNJGJMPUP NPEFMT EP OPU OFFE UP CF MPXFSFE CZ NN Fig 7 Mod DG Mod DGW ...

Page 11: ...of the working area thattheplantis fitted withan efficient earthconnection following the standards and law provisions in force The earth connection iscompulsory in terms of the law Should there be no cable and or plug on the equipment use suitable absorption material for the working temperature as well as indicated on the matrix plate Under no circumstance must the cable reach a temperature above ...

Page 12: ...lame display levels will show the indication if the minimum level programmed corresponds with the factory setting and the indication will change or v in flashing mode indicating a higher or lower capacity than that programmed The procedure ends by pressing the PT key The minimum capacity levels will then be acquired and memorised by the device and will be used in the normal use of the hob Selectin...

Page 13: ...e circuit Replace the device Flt09 Generic anomaly Power was cut to the device when another type of failure had occurred previously Unlock the burners Resonator anomaly Failure at the circuit Replace the device Flt0A All burners locked No gas Restore the gas and unlock the burners Ionization electrodes dirty or not hit by the flame Clean or reposition the electrodes and unlock the burners The cook...

Page 14: ...PG 43 8 MJ h Total gas consumption for Model GE12 10 on Natural gas 44 2 MJ h and propane LPG 43 8 MJ h Total gas consumption for Model DG on Natural gas 37 6 MJ h and propane LPG 37 1 MJ h Total gas consumption for Model GE7 10 on Natural gas 16 0 MJ h and propane LPG 16 0 MJ h Total gas consumption for Model DGW on Natural gas 15 5 MJ h and propane LPG 15 3 MJ h 0 92 1 17 1 63 1 86 2 x outer 1 1...

Page 15: ...table physical or operating environment 3 Warranty Claim 3 1 To make a Claim you must a Contact your nearest Local Servicing Agent details of which are on Fulgor Milano Australasia s website listed above and b Provide Proof of Purchase and this Warranty to the Local Servicing Agent 3 2 Upon receipt of a valid Claim a Local Servicing Agent will attend your premises to inspectthe Product 3 3 Where a...

Page 16: ... with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure 5 Claim means a claim made under t...

Reviews: