ENGLISH
FLUSH INSTALLATION
Ltr.
DIMENSION
F
Cutout Width
G
Cutout Height
H
Visible part of the mounting strips
SINGLE
30”
30 1/16”
(76,4 cm)
28
1/32
”
(71
,2
cm)
3/4”
(1,9 cm)
Mounting strip
Finished sides
the cabinet)
(61 cm)
I
Cutout Depth
24”
ENGLISH
ELECTRICAL SUPPLY
Location of rating plate
WIRING REQUIREMENTS
When making the wire connections, use the entire
length of the conduit provided (3 feet). The conduit
must not be cut.
Before making connections make sure the power is off
and read and observe the following:
1. A separate three-wire or four-wire, single phase,
.
2
3.
In the United States:
Wiring must conform to the National Electrical
Code, ANSI/NFPA No. 7 latest edition. You can
obtain a copy of the National Electrical Code by
writing to: National Fire Protection Association
Batterymarch Park Quincy, MA 02269
In Canada:
Wiring must conform to Canadian Electrical Code
C22.1- latest edition. You can obtain a copy of the
Canadian Electrical Code by writing to: Canadian
Standards Association 178 Rexdale Boulevard
Rexdale (Toronto), Ontario, Canada M9W 1R3
4.
connections must be suitable for the rating of the
appliance as per the National Electrical Code
requirements. The flexible armoured cable
extending from the oven should be connected
directly to the junction box.
5. The junction box should be located so as to allow
as much slack as possible between the junction
box and the oven so it can be moved if servicing is
ever required.
6. A U.L. listed conduit connector must be provided
at each end of the power supply cable.
This option is provided for areas where standard 240V service is
not available. This option must be accessed with the oven connected
to power source, and using the following sequence:
The voltage setting is stored and kept even after a long power-off.
WARNING
ELECTRICAL SHOCK HAZARD
The electrical power to the oven branch circuit must be shut off
while line connections are being made.
Do not use an extension cord with this appliance.
Electrical ground is required on this appliance. The free end of the
green wire (the ground wire) must be connected to a suitable
ground. This wire must remain grounded to the oven.
If cold water pipe is interrupted by plastic, non metallic gaskets,
union connections or other insulating materials, DO NOT use for
grounding.
DO NOT ground to a gas pipe.
DO NOT have a fuse in the NEUTRAL or GROUNDING circuit. A
fuse in the NEUTRAL or GROUNDING circuit could result in an
electrical shock.
Check with a qualified electrician if you are in doubt as to whether
the appliance is properly grounded.
Failure to follow these instructions could result in serious injury or
death.
CAUTION
Do not repair or replace any part of the appliance unless specifically
recommended in the manual. All other servicing should be done by a
qualified technician. This may reduce the risk of personal injury and
damage to the oven.
Never modify or alter the construction of the appliance by removing
panels, wire covers, screws, or any other part of the product.
The oven must be connected with Copper or
Aluminum wire.
Wire size (Copper or Aluminum wire) and
120V/240V, 60 Hz or 120V/208V, 60 Hz branch
circuit is required for the oven.
6
ENGLISH
Installation Manual
Summary of Contents for MILANO
Page 2: ......
Page 21: ...Notes 21 ...
Page 22: ...Notes 09FL5960 12 14 22 ...
Page 23: ......
Page 24: ...09FL5960 12 14 ...