F0.13 AVR selection
0 I nv a li d
:
1 Valid all the time
:
1
13 .
※
F0 Basic Function Parameters
Function
Code
Name
Setting Range
Modifi
cation
Serial
No
F0. 00 Cont r ol mode
0 Speed sensorless vector
control (SVC)
:
1 V/ F c ontr ol
:
1
F0.01
Command source
selection
0 K e yb o ar d
:
1 Ter minal
:
2 Communi c ati on
:
0
F0.02
Keyboard and terminal
UP/DOWN setting
1 Valid, and inverter does not
memorize when power down
:
2 I nv al id
:
0
F0.03
Frequency command
Selection
0 K e yb o ar d
:
4: Multi-speed
5: PID control
6: Communication
1 VI
:
2 CI
:
3 V I+ C I
:
0
F0.04
Maximum output frequency
10. 00 600.00Hz
~
50.00Hz
F0.05
Upper limit frequency
F0.06 F0. 04
~
50.00Hz
F0.06
Lower limit frequency
0. 00 Hz F0. 05
~
0.00Hz
F0.07
Keyboard frequency setting 0.00 Hz F0.04
~
50.00Hz
F0.08 ACCEL time 1
0.1 3600. 0s
~
10.0s
F0.09
DECEL time 1
0. 1 3600. 0s
~
10.0s
F0.10
Operation direction
selection
0 Operating at default direction
:
1 Operating at reverse direction
:
2 NO inverse operating
:
2
F0.11
Carrier frequency setting
1. 0 15. 0k Hz
~
Set by
model
F0.12
Functional parameters
restoration
0 NO operat ion
:
1 Restore default value
:
0
●
0.
1.
※
2.
3.
4.
5.
6.
7.
8.
9.
10 .
11.
12 .
●
※
※
※
※
※
※
※
●
●
●
2 Delete failure records
:
Function
Code
Name
Setting Range
Modifi
cation
Serial
No
2 Invalid during deceleration
:
F0.14
Start Mode
0 Di rec t s t art
:
1 DC braking first and then start
:
2 Running speed pick-up and
then start
:
0
F0.15
Start frequency
0. 00 10. 00Hz
~
0.50Hz
F0.16
Hold time of start
frequency
0 .0 5 0 .0 s
~
0.0s
F0.17
Braking current
before starting
0 .0 1 5 0. 0 %
~
0.0%
F0.18
Braking time
before starting
0 .0 5 0 .0 s
~
0.0s
F0.19
Stop Mode
0 DECEL St op
:
1 Fr ee run St op
:
0
F0.20
Beginning Frequency of
braking
0 .0 0 F 0. 04
~
0.00Hz
F0.21
Waiting time of braking
0 .0 5 0 .0 s
~
0.0s
F0.22
DC braking current
0 .0 1 5 0. 0 %
~
0.0%
F0.23
DC braking time
0 .0 5 0 .0 s
~
0.0s
F0.24
Dead time between
forward and reverse
0. 0 3600. 0s
~
0.0s
F0.25
Terminal command
protection when
power on
0 Terminal command invalid
when power on
:
1 Terminal command valid when
power on
:
0 1
~
F1.00
Inverter model
0 B m ode l
:
1 P m o de l
:
F1.01
Motor rated power
0. 4 900.0k W
~
50.00Hz
0. 01Hz F0. 04
~
Motor rated frequency
0 36000rpm
~
Motor rated speed
0 46 0V
~
Motor rated voltage
0. 1 1000. 0A
~
Motor rated current
0. 001 65.535
~
Ω
Motor stator resistance
F1.02
F1.03
F1.04
F1.05
F1.06
14 .
15 .
16 .
17 .
18 .
19 .
20 .
21 .
22 .
23 .
24 .
25 .
26 .
27 .
28 .
29 .
30 .
31 .
32 .
※
※
※
※
※
※
※
※
※
※
※
※
●
●
●
●
●
●
●
F1 Motor Parameters
Set by
model
Set by
model
Set by
model
Set by
model
Set by
model
Set by
model
F1.07
Motor rotor resistance
0. 001 65.535
~
Ω
F1.08
Motor stator/rotor
inductance
0. 1 6553. 5mH
~
33 .
34 .
※
※
Set by
model
Set by
model
Default
Value
Default
Value
Chapter 5 Function Parameters List
DZB Series
Chapter 5 Function Parameters List
DZB Series
0 Valid, and inverter memorize
when power down
:
Ch
t
5 F
ti
P
t
Li t
DZB Series
Ch
t
5 F
ti
P
t
Li t
DZB0 Series