5/14/2018
Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual
16/54
- 2 5 -
- 2 6 -
Function
Code
Name
Setting Range
Modifi
cation
Serial
No
F1.09
Mutual inductance of
motor stator/rotor
0. 1 6553. 5mH
~
F1.10
No-load current
0. 01 655. 35A
~
F1.11
Self-learning of
motor parameters
(Invalid for DZB200)
0 NO operat ion
:
1
Self-learning
:
complete tuning
2
:
static tuning Self-learning
0
F1.12
Speed loop proportional
gain1
0 1 00
~
30
F1.13
Speed loop integral time1
0. 01 10.00s
~
0.50s
35 .
36 .
37 .
38 .
39 .
F1.14
Switching low
point frequency
0. 00Hz F1.1 7
~
5.00Hz
40.
F1.15
Speed loop proportional
gain 2
0 1 00
~
25
41.
F1.16
Speed loop integral
time 2
0. 01 10.00s
~
1.0 0s
42.
F1.17
Switching high
point frequency
F1.14 F0. 04
~
10.00Hz
43.
F1.18
VC slip compensating
factor
5 0 % 2 0 0%
~
100%
44.
●
※
※
※
※
※
※
※
※
※
F2.00
On-off signal filter times
1 10
~
5
51.
F2.01
S1 Terminal Function
Selection
0:No Function
1:Forward
52 .
F2.02
2
53 .
※
●
●
1
S2 Terminal Function
Selection
F2 Input and Output Terminal Function Parameters
Set by
model
Set by
model
F1.19
Upper torque limit setting
0.0 200.0%(inverter rated current)
~
150.0%
45.
F1.20
V/F curve setting
0 Linear V/F curve
:
1 square torque V/F curve
:
0
46.
F1.21
Torque boost
0. 0% (auto)
:
0.1
30 .0
%~
%
0
47.
F1.22
Torque bo ost cut-off
0.0% 50.0% (relative to motor
rated frequency)
~
20.0%
48 .
F1.23
V/F slip compensation limit 0 . 0 2 0 0. 0%
~
100%
49 .
F1.24
Energy Conservation
Selection
0
**
50 .
※
※
●
●
※
2:Reverse
5:Reverse Jogging
3:three-wire control
4:Forward Jogging
F2.03
4
54 .
F2.04
7
55.
●
●
S3 Terminal Function
Selection
S4 Terminal Function
Selection
6:Free run stop
7:Failure reset
8:External fault input
9:Frequency setting(UP)
10:Frequency setting(DOWN)
11:Frequency up/down setting
clear
16:PID control pause
17:Traverse pause at current
frequency
18:Traverse reset
19:ACCEL/DECEL forbid
20 25: Res er ved
~
F2.0 6
13
57 .
F2.07
Terminal control
mode
0 two-wire control 1
:
1 two-wire control 2
:
2 three-wire control 1
:
3 three-wire control 2
:
0
58.
F2.08
UP/DOWN frequency
increment variable rate
0. 01 50. 00Hz /s
~
0.50Hz/s
59.
F2.09
VI lower limit
0. 00V 10. 00V
~
0.00V
60 .
F2.10
VI lower limit
corresponding setting
- 100. 0% 100.0%
~
0.0%
61 .
F2.11
VI upper limit
0. 00V 10. 00V
~
10.00V
62.
F2.12
VI upper limit
corresponding setting
- 100. 0% 100.0%
~
100.0%
63 .
F2.13
VI input filtering time
0. 00s 10. 00s
~
0.10s
64.
F2.14
CI lower limit
0. 00V 10. 00V
~
0.0 0V
65.
●
●
※
※
※
※
※
※
※
S6 Terminal F unction
Selection
F2.05
12
56 .
●
S5 Terminal F unction
Selection
12:Multi-Speed Terminal 1
13:Multi-Speed Terminal 2
14:Multi-Speed Terminal 3
15:ACCEL/DECEL Time selection
Function
Code
Name
Setting Range
Modifi
cation
Serial
No
F2.15
CI lower limit
corresponding setting
- 100. 0% 100.0%
~
0.0%
66.
F2.16
CIupper limit
0. 00V 10. 00V
~
10.00V
67.
※
※
Default
Value
Default
Value
0:No Operation
1:Energy Conservation
Chapter 5 Function Parameters List
DZB Series
Chapter 5 Function Parameters List
DZB0 Series
Chapter 5 Function Parameters List
DZB Series
Chapter 5 Function Parameters List
DZB Series