- 2 7 -
- 2 8 -
Function
Code
Name
Setting Range
Modifi
cation
Serial
No
F2.22
FM
outp ut
selection
Analog
1 Running frequency
:
0 Setting frequency
:
4 Runni ng s peed
:
2 Output current
:
3 Output v ol tage
:
5 Output power
:
6 Output t orque
:
7 VI i nput v alue
:
8 CI input value
:
9 10
~
:
Reserved
0
73.
F2.23
AO Lowe r limit
0.0% 100.0%
~
0.0%
74 .
F2.24
Lower limit corresponding
AO output
0. 00V 10. 00V
~
0.00V
75.
F2.25
AO Upper limit
0. 0% 100.0%
~
100.0%
76 .
Upper limit corresponding
AO output
0. 00V 10. 00V
~
10.00V
77 .
F3.00
User password
0 6 55 35
~
0
78.
F2.26
※
※
※
※
※
※
F3 Human Machine Interface Parameters
F2.17
CI upper limit
corresponding setting
- 100. 0% 100.0%
~
100.0%
68 .
F2.18
CI input filtering time
0. 00s 10. 00s
~
0.10s
69.
F2.19
Mo1output selection
0 NO output
:
4 Motor running forward
:
5 Motor running reverse
:
3 Faul t out put
:
2 FDT out put
:
1 Frequency reached
:
6 Null speed operating
:
7 Upper limit frequency reached
:
8 Lower limit frequency reached
:
9 1 0 R es er ve d
~
:
1
70.
F2.20
Mo2output selection
2
71 .
F2.21
Relay output selection
3
72.
※
※
※
※
※
Function
Code
Name
Setting Range
Modifi
cation
Serial
No
F3.01
Reserved
79 .
F3.02
Reserved
80 .
F3.03
STOP function option
1 Keypad and terminal control
valid
:
0 Keypad control valid
:
2 Keypad and communication
control valid
:
3 All control modes valid
:
0
81.
F3.04
Keypad display option
0
82.
0 external keyboard preferential
ENB
:
1 Local and external keyboard
simultaneous display, only
external key-press is valid.
:
2 Local panel and external
keyboard simultaneous display,
only Local key-press is valid.
:
3 Localand externalkeyboard
simultaneous display, and all
key-presses are valid (both are
OR logical relation)
:
※
※
F3.05
255
83.
1
2
4
8
16
32
64
12 8
25 6
51 2
1024
2048
4096
8192
16384
※
Code
Displayed Message
0:Setting frequency
1:Running frequency
2:Output current
3:Output voltage
4:Running speed
5:Output power
6:Output torque
7:DC bus voltage
8:PID setpoint
9:PID feedback
10:Input terminal status
11:Output terminal status
12:VI value
13:CI value
14:Current segment of
multi-speed control
operationstatus display
parameter option
1
2
Setting frequency
DC bus voltage
255
84.
F3.06
※
Stop status display
parameter option
Default
Value
Default
Value