Function
Code
Name
Setting Range
Modifi
cation
Serial
No
Function
Code
Name
Setting Range
Modifi
cation
Serial
No
18:Communication fault(E018)
19:Current detect error(E015)
20:Motor self-learning error(E016)
21:EEPROM operation error
(E00F)
22:PID feedback disconnect error
(E02E)
23:Braking uniterror E01A
(
)
24:Reserved
F3.14
Operating frequency at
current fault
0.00Hz
92.
F3.15
Output amperage at
current fault
0.0A
93.
F3.16
Bus voltage at current fault
0.0V
94.
F3.17
Input terminal status at
current fault
0
95.
F3.18
Output terminal status at
current fault
0
96.
F4.00
ACCEL Time 2
0.1 3600.0s
~
10.0s
97.
F4.01
DECELTime 2
0.1 3600.0s
~
10.0s
98.
F4.02
Jogging frequency
0 .0 0 F 0 .0 4
~
5.00Hz
99.
F4.03
JoggingACCEL time
0.1 3600.0s
~
10.0s
100.
F4.04
Jogging DECEL time
0.1 3600.0s
~
10.0s
101.
F4.05
Skip frequency
0 .0 0 F 0 .0 4
~
0.00Hz
102.
F4.06
Skip frequency range
0 .0 0 F 0 .0 4
~
0.00Hz
103.
F4.07
Traverse frequency range
0.0 100.0%
relative to set frequency
~
(
)
0.0%
104.
F4.08
Kick frequency range
0.0 50.0%(relativeto traverse
frequency range)
~
0.0%
105.
F4.09
Traverse frequency up
time
0.1 3600.0s
~
5.0s
106.
F4.10
Traverse frequency down
time
0.1 3600.0s
~
5.0s
107.
**
**
**
**
**
※
※
※
※
※
※
※
※
※
※
※
F4 Application Function Parameters
4
8
16
32
64
128
256
Input terminal status
Output terminal status
PID setpoint
PID feedback
VI value
CI value
Current segment of
multi-speed control
F4.11
Fault auto-reset times
0 3
~
0
108.
※
F4.12
Interval time setting of
automatic resetting fault
0.1 100.0s
~
1.0s
109.
※
Default
Value
Default
Value
Chapter 5 Function Parameters List
Chapter 5 Function Parameters List
F3.07
85.
※
0-14 (0:invalid)
operation status display
p eferential option
r
0
16:IGBT module overheat fault
(E01E)
17:External fault(E017)
IGBT module temperature
F3.08
0 100.0
~
℃
86.
F3.09
Software version
87.
F3.10
Accumulative operating
time
0 65535h
~
0
88.
F3.11
The fault before previous
fault type
89.
0 No fault
:
1:IGBT U phase protection(E009)
4:Acceleration over-current(E004)
5:Deceleration over-current(E005)
6:Constant speed over-current
(E006)
7:Acceleration over-voltage(E002)
8:Deceleration over-voltage(E00A)
9:Constant speed over-voltage
(E003)
10:Bus under-voltage fault E001
(
)
11:Motor overload(E007)
12:Inverter o verload(E008)
13:Input side phase failure(E012)
14:Output side phase failure(E013)
15:(Diode module overheat fault
(E00E)
F3.12
Previous fault type
90.
F3.13
Current fault type
91.
**
**
**
**
**
**
2:IGBT V phase protection(E019)
3:IGBT W phase protection(E029)
Chapter 5 Function Parameters List
DZB Series
Chapter 5 Function Parameters List
DZB Series