background image

9

AIR COMPRESSOR SAFETY WARNINGS (cont.)

¥  Pull the ring on the safety valve daily to ensure that it operating properly and to clear any 

possible debris from the outlet.

¥  Keep the compressor at least 300mm from the nearest wall to ensure adequate 

ventilation for cooling purposes.

¥  Before transporting the compressor make sure that the pressurised air is bled from the 

tank and that the compressor is firmly secured.

¥  Protect the air hose and cordset from damage. Inspect for weak or worn spots regularly 

and replace if necessary.

¥  Avoid using an extension cord with this product. Use additional air hose instead of an 

extension cord to prevent power loss and possible damage to the motor. 

¥  After long working periods external metal parts could be hot.

¥  Always press the on/off button down to switch off the compressor before switching off 

the power or removing the power plug.

¥  After using the compressor, switch off the on/off button, disconnect the power supply 

and open the outlet valve to release the pressure.

¥  Never attempt to remove any part of the compressor whilst the tank is under pressure.

Wear goggles, wear earmuffs, wear a breathing mask

Never apply the outlet air of this compressor directly on to any part of a persons body. Do 

not attempt to block the air outlet with your finger or any part of your body.
The tool must be used only for its prescribed purpose. Any use other than those mentioned 

in this Manual will be considered a case of misuse. The user and not the manufacturer shall 

be liable for any damage or injury resulting from such cases of misuse.
The manufacturer shall not be liable for any changes made to the tool nor for any damage 

resulting from such changes.
Even when the tool is used as prescribed it is not possible to eliminate all residual risk 

factors. The following hazards may arise in connection with the tools construction and 

design:
¥  Damage to the lungs if an effective breathing mask is not worn.

¥  Damage to hearing if effective earmuffs are not worn.

¥  Damage to the eyes if effective safety goggles or shield are not worn.

WARNING!

 In the event that an air line is cut or broken, the air supply must be turned 

off at the compressor. A broken air line which is not supported is extremely dangerous 

and can whip around very quickly, both with the capability of striking people, and 

blowing foreign particles into the air.
Do not attempt to catch the air line but immediately keep bystanders well clear and 

turn off the air supply to the hose, turn off the compressor at the On / Off button, 

and then remove the hose from the compressor.

Summary of Contents for FBACVT-5030

Page 1: ...GES 2 AIR OUTLETS INSTRUCTION MANUAL WARNING Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save...

Page 2: ...livery FAD 164 l min Tank Volume 50 l Max Working Pressure 10 bar 145 psi Oil SAE 15W 40 IP Rating IP20 Weight 46 kg Free Air Delivery The free air delivery value was measured in accordance with Claus...

Page 3: ...eather oil filler opening 10 ON OFF Switch 11 Oil Drainage Screw Oil level window 12 Regulated Output Pressure Gauge 13 Quick lock Coupling regulated compressed air 14 Pressure Regulator 15 Tank Press...

Page 4: ...OUR PRODUCT Page 02 INTRODUCTION Page 05 SAFETY INSTRUCTIONS Page 05 ASSEMBLY Page 10 OPERATION Page 13 MAINTENANCE Page 15 TROUBLE SHOOTING Page 17 DESCRIPTION OF SYMBOLS Page 18 CONTENTS Page 18 WAR...

Page 5: ...or has been designed for 230V and 240V only Always check that the power supply corresponds to the voltage on the rating plate Note The supply of 230V and 240V on Full Boar tools are interchangeable fo...

Page 6: ...tions Water entering a power tool will increase the risk of electric shock d Do not abuse the cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sha...

Page 7: ...from the power source and or the battery pack from the power tool before making any adjustments changing accessories or storing power tools Such preventive safety measures reduce the risk of starting...

Page 8: ...ressurised air to bleed from the tank from the safety valve and then remove the electrical plug from the power supply Check the maximum pressure rating of any tools or accessories that you intend usin...

Page 9: ...ssor directly on to any part of a persons body Do not attempt to block the air outlet with your finger or any part of your body The tool must be used only for its prescribed purpose Any use other than...

Page 10: ...air is dry and dust free Do not set up the compressor in damp or wet areas The compressor may only be used in suitable areas with good ventilation and an ambient temperature from 5 C to 40 C There mus...

Page 11: ...Place the support foot bolt up through the hole in the supporting bracket 2 Secure the support foot in place with the nut 3 Repeat steps 1 and 2 to fit the second foot Replacing the air breather 9 Fi...

Page 12: ...Secure the assembly by tightening the screw into the top of the filter Installation of the intake air filter 2 Fig 5 1 Remove the shipping plug with a screwdriver or similar 2 Screw the assembled int...

Page 13: ...cted and the task at hand 1 To do so first back the pressure off by turning the pressure regulator 14 anti clockwise 2 Set the pressure by turning the pressure regulator clockwise until the desired pr...

Page 14: ...ssure 10 bar is reached Fig 9 2 Hold the ring on the safety relief valve and pull it outwards Air should discharge from the valve Fig 10 3 When the ring on the safety relief valve is released the air...

Page 15: ...ief valve or remove its seal Check the oil level at regular intervals Place the compressor on a level and straight surface The oil level must be between the two marks MAX and MIN on the oil level wind...

Page 16: ...ast every 300 hours in service A clogged intake filter will decrease the compressors performance dramatically 1 Remove the air intake filter from the compressor and undo the screw on the top of the ai...

Page 17: ...ed by a service centre The drainage valve leaks Ensure it is shut off properly The compressor starts pressure is shown on the pressure gauge but no pressure to the air tool Loose hose connections Chec...