Engine oil inspection
Note:
This unit is fitted with an oil sensor. Failure to fill the engine oil sump to
maximum level (600ml) before first use may result in inability to start the plate
compactor.
Before starting ensure an oil inspection is conducted. Always use high quality oils,
select their viscosity grade according to the operating temperatures.
1.
Remove engine oil fill plug (10) and clean on a cloth or rag.
2.
Re-insert the oil fill plug momentarily. Remove and look at the oil fill plug to
determine oil level.
3.
If oil level is low, fill engine sump with oil.
4.
After finishing, replace and secure the oil fill plug.
Note:
It is recommended that SAE-10W-30 (multi viscosity) oils are used at
temperatures from 5 to 35ºC and synthetic oils 5W-30 (multi viscosity) is used for
temperatures -5 to 5ºC.
To change or top up the engine oil, refer to either the maintenance section (pg 15)
of this instruction manual.
PRE-OPERATION INSPECTION
WARNING!
Engine oil has been drained for shipping. Failure to fill engine sump
with oil before starting the engine may result in permanent damage and will void
warranty.
Environment conditions
The operation of a four-stroke (91 unleaded) engine is affected by:
1. Temperature
a.
Working in low temperatures could lead to difficult cold starting.
b.
Working in very high temperatures could lead to difficult hot starting due to
evaporation of the fuel.
c.
Ensure the correct oil is used according to the operating temperatures. (Refer to
Engine Oil Inspection on this page).
2. Altitude
a.
When there is a considerable increase in altitude, the load on the machine
should be reduced and heavy work load should be avoided.