Filling with oil
Recommended lubricating oil: SAE 5W/40 or an alternative of the same quality. On the
market also a special compressor oil with the oil type name: L-DAB-46-A is available. Do not
mix up different oils when refilling. It should be refilled for the first time after 100 hours of
operation. Thereafter the oil should be drained and refilled after every 500 hours in service.
1.
Unscrew and remove the oil sealing plug (15) (Fig. 19).
2.
Fill the crank case until the oil level reaches the mid point
of the red circle in the oil level window (18) (Fig. 20)
This should be approximately 230ml of oil.
3.
Screw the oil sealing plug (15) firmly in position.