background image

KNOW YOUR PRODUCT

•  3.0HP, 50L TANK

•  164L/MIN FREE 

AIR DELIVERY

•  DUAL PRESSURE 

GAUGES 

•  10 BAR PRESSURE

•  2 AIR OUTLETS

ORIGINAL INSTRUCTIONS

WARNING: Read all safety warnings and instructions before use. Failure 

to follow the warnings and instructions may result in electric shock, fire and/or 

serious injury. Save these instructions for future reference.

0816

V-TWIN AIR

COMPRESSOR

Summary of Contents for V-TWIN FBACVT-5030U

Page 1: ...BAR PRESSURE 2 AIR OUTLETS ORIGINAL INSTRUCTIONS WARNING Read all safety warnings and instructions before use Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save these instructions for future reference 0816 V TWIN AIR COMPRESSOR ...

Page 2: ...FAD 164 l min Tank Volume 50 l Max Working Pressure 10 bar 145 psi Oil SAE 15W40 L DAB 46 A IP Rating IP20 Weight 46 kg Free Air Delivery The free air delivery value was measured in accordance with Clause 4 2 of AS 4637 SPECIFICATIONS MODEL NO FBACVT 5030U KNOW YOUR PRODUCT 2 3 4 5 6 8 7 1 ...

Page 3: ...reather oil filler opening 10 ON OFF Switch 11 Oil Drainage Screw Oil level window 12 Regulated Output Pressure Gauge 13 Quick lock Coupling regulated compressed air 14 Pressure Regulator 15 Tank Pressure Gauge 16 Safety Relief Valve 17 Quick lock Coupling unregulated compressed air psi bar 2 4 6 8 10 150 200 100 50 1 psi 50 150 200 100 4 6 8 10 12 bar 9 10 11 12 13 14 15 16 17 ...

Page 4: ...YOUR PRODUCT Page 02 INTRODUCTION Page 05 SAFETY INSTRUCTIONS Page 05 ASSEMBLY Page 10 OPERATION Page 13 MAINTENANCE Page 15 TROUBLE SHOOTING Page 17 DESCRIPTION OF SYMBOLS Page 18 CONTENTS Page 18 WARRANTY Page 20 TABLE OF CONTENTS ...

Page 5: ...erence Before you connect the equipment to the mains supply make sure that the data on the rating plate are identical to the mains data The power supply for this product should be protected by a residual current device rated at 30mA or less A residual current device reduces the risk of electric shock If the supply cord is damaged it must be replaced by an electrician or a power tool repairer in or...

Page 6: ...ions Water entering a power tool will increase the risk of electric shock d Do not abuse the cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock e When operating a power tool outdoors use an extension cord suitable for outdoor use Use of a cord suitable for ...

Page 7: ...g from the power source and or the battery pack from the power tool before making any adjustments changing accessories or storing power tools Such preventive safety measures reduce the risk of starting the power tool accidentally d Store idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool Power tools ...

Page 8: ...ressurised air to bleed from the tank from the safety valve and then remove the electrical plug from the power supply Check the maximum pressure rating of any tools or accessories that you intend to use with the compressor The output pressure of the air from the compressor must be regulated so that it never exceeds the rated pressure of the tool or accessory To avoid the risk of burns and injury f...

Page 9: ...essor directly on to any part of a persons body Do not attempt to block the air outlet with your finger or any part of your body The tool must be used only for its prescribed purpose Any use other than those mentioned in this Manual will be considered a case of misuse The user and not the manufacturer shall be liable for any damage or injury resulting from such cases of misuse The manufacturer sha...

Page 10: ... is dry and dust free Do not set up the compressor in damp or wet areas The compressor may only be used in suitable areas with good ventilation and an ambient temperature from 5 C to 40 C There must be no dust acids vapours explosive gases or flammable gases in the room Your compressor pump is shipped with oil but must be checked before putting the equipment into operation ASSEMBLY WARNING During ...

Page 11: ...1 Place the support foot bolt up through the hole in the supporting bracket 2 Secure the support foot in place with the nut 3 Repeat steps 1 and 2 to fit the second foot Replacing the air breather 9 Fig 3 1 Remove the transportation plug from the oil filler opening with a screwdriver 2 Screw the supplied air breather into the oil filler opening Note The compressor pump is shipped with oil but must...

Page 12: ...2 Secure the assembly by tightening the screw into the top of the filter Installation of the intake air filter 2 Fig 5 1 Remove the shipping plug with a screwdriver or similar 2 Screw the assembled intake air filter securely to the compressor by rotating it clockwise 3 Repeat this process for the second intake air filter ASSEMBLY cont IMPORTANT Never use the air compressor without a filter Check t...

Page 13: ...ected and the task at hand 1 To do so first back the pressure off by turning the pressure regulator 14 anti clockwise 2 Set the pressure by turning the pressure regulator clockwise until the desired pressure is met on the regulated pressure gauge left OPERATION IMPORTANT The motor is fitted with an overload switch If the compressor overloads the overload switch switches off the equipment automatic...

Page 14: ...essure 10 bar is reached Fig 9 2 Hold the ring on the safety relief valve and pull it outwards Air should discharge from the valve Fig 10 3 When the ring on the safety relief valve is released the air discharge should stop Fig 11 psi bar 2 4 6 8 10 150 200 100 50 1 psi 50 150 200 100 4 6 8 10 12 bar psi bar 2 4 6 8 10 150 200 100 50 1 psi 50 150 200 100 4 6 8 10 12 bar psi bar 2 4 6 8 10 150 200 1...

Page 15: ...ls Place the compressor on a level and straight surface The oil level must be between the two marks MAX and MIN on the oil level window 11 Fig 12 Recommended lubricating oil SAE 15W 40 or an alternative of the same quality On the market also a special compressor oil with the oil type name L DAB 46 A is available Do not mix up different oils when refilling It should be refilled for the first time a...

Page 16: ...east every 300 hours in service A clogged intake filter will decrease the compressors performance dramatically 1 Remove the air intake filter from the compressor and undo the screw on the top of the air filter as shown in Fig 14 2 You can then remove the filter pad from the two halves of the plastic housing tap it to remove the dirt blast it down with low pressure compressed air approx 3 bar and r...

Page 17: ...y remedy the cause of the overheating Overloaded Reset overload switch The compressor starts but there is no pressure Leak in the non return valve Replace the non return valve The seals are damaged Check the seals and have any damaged seals replaced by a service centre The drainage valve leaks Ensure it is shut off properly The compressor starts pressure is shown on the pressure gauge but no press...

Page 18: ...arts 93 Sound power level Pressure rating bar l Litres Ingress protection from water lP20 Warning The equipment is remote controlled and may start up without warning Bunnings 489 499 Avebury Boulevard MK9 2NW CONTENTS 1x FBACVT 5030 Air Compressor 2x Wheels 2x Wheel Bolt 2x Wheel Fasteners and Washers 2x Air Filter 2x Rubber Support Feet 2x Support Feet Fasteners 1x Instruction Manual DESCRIPTION ...

Page 19: ...the device to abnormal environmental conditions or by lack of care and maintenance Damage to the device caused by abuse or incorrect use for example overloading the device or the use or unapproved tools or accessories ingress of foreign bodies into the device such as sand stones or dust transport damage the use of force or damage caused by external forces for example by dropping it Damage to the d...

Page 20: ...20 ...

Reviews: