According to the chapters of norm IEC 60364:
Install
on the power supply
Sensor cables and signal cables of the computer may be joined, but not in the same electric conduit
through which the electric input and the activation of the loads run
Install transient suppresors (RC filters) parallel to the loads as to increase the product life of the
relays.
protector against overvoltage
Schematic for the connection of supresors
to contactors
Suppresor
A1
A2
A1 and A2 are the
contactor coil terminals.
Schematic for the connection of supresors to
direct activation loads
Load
Suppresor
For direct activation the maximum
specified current should be taken
into consideration.
PROTECTIVE VINYL:
This adhesive vinyl (included inside the packing) protects the instruments against
water drippings, as in commercial refrigerators, for example.
Do the application after finishing the electrical connections.
Remove the protective paper
and apply the vinyl on the entire
superior part of the device,
folding the flaps as indicated by
the arrows.
5.2 - View maximum and minimum temperature
6. SIGNALLING
By pressing key
one can view the minimum and maximum thermostat temperature. On pressing key
(short touch), the minimum temperature shall be displayed, followed by the maximum temperature.
If the key
remains pressed in, the values will be reinitialized and the message
will be shown in
the display.
- Thermostat sensor disconnected or out of range
- Configuration parameters not programmed or out of range
Led
- Currently active event
EVENT
5.3 - Manual events activation
Pressing the
key for 10 seconds, manually activate an event. It will be deactivated after the time
adjusted in the function elapses
.
If the
key is pressed again for 10 seconds, the manual drive will be disabled.
To deactivate the manual activation, all you have to do is configure function
with the value " 000".
The display will show the
message when the manual drive is enabled and the
message
when the manual drive is disabled.
8. WIRING DIAGRAM
72 mm
29
mm
Dimension of the clipping
for setting of the instrument
in panel
7. UNIT SELECTION(°C / °F)
To define the unit that the system will use to operate, enter into the functions menu
using the
access code ”231” and confirm it by hitting key
. The indication
will appear, then press
or
to choose between
or
and confirm with key
. After selecting the unit the
figure will appear, and the instrument will return to the function
. Whenever the unit is
altered, the parameters should be reconfigured, since they assume “standard” values.
SET
SET
Sensor
Power
supply
Load
COMMON
Load
supply
NO
NC
1 2 3 4 5 6 7 8 9 10 11 12
115 V
(12 V)
230 V
(24 V)
0
THERM
7 - 8
7 - 9
115V
230V
12V
24V
RT-607Ri power RT-607RiL power