K 1
K2
Sx(FWD)
Sx(REV )
DCM
DZB
Series
OFF
OFF
Op era tion
Comm and
K1
K 2
ON
OFF
OFF
ON
ON
ON
STOP
FWD
REV
STOP
This paramet er defines four di fferent control modes which controls the inverter operat ion through
external terminals.
0: Two-wire t ype control, integrat e Enabl e wit h di rection. Thi s mode is the most often used two-wire
control mode. The motor forwa rd and revers e ope rations are determi ned by the defined FWD and REV
t erminal command.
Fig. 6-8 Two-wire operation mode 1
1: Two-wire c ontrol , s eparate Enable from direction. When this mode i s used, the defined F WD is enable
t erminal. The direction is determined by the defined REV state.
Fig. 6-9 Two-wire operation mode 2
K 1
K2
Sx( FWD)
Sx(REV)
DCM
DZB
Series
OFF
OFF
K1
K2
ON
OFF
OFF
ON
ON
ON
Op era tion
Comm and
FWD
REV
STOP
STOP
Cha pter 6 Parameter D es cription
DZB Series
F2.0 7
Ter mi nal control
mode
0
two-wire control 1
:
1
two-wire control 2
:
2
three-wire control 1
:
3
three-wire control 2
:
0
Function
Code
Name
Se tting Range
Defa ult
Value
- 47-
3: Three-wire control, se parate Enabl e from direction. At this mode EN is the Enable terminal, SW1 or
S W2 define operati ng c ommand and control direct ion at the s ame time. Stop command is defined by SW2.
SW1
F WD operati ng but ton
SW 2
STOP button
SW3
REV operating but ton
:
:
:
EN i s defining the corresponding terminal function as F unction 3
Three-wire operat ion cont rol
.
“
”
N ote: For two-wire operation mode, when F WD/RE V t erminal is enabled and th e stop comman d
produced by other sources stops t he equipment, the inverter does not start to operate after the s top
comman d disappears even if the con trol terminal FWD /REV is still valid. If the i nv erter needs to
operate, it is required to trigger FWD/RE V again.
F ig. 6-11 Three-wire operat ion mode 2
Sx(FWD)
Sx(EN)
Sx(RE V)
DCM
SW1
SW2
S W3
DZB
Series
Chapter 6 Para meter Description
DZB Series
2: Three- wire control 1, integrate Enable with di rection. At this mode, EN is the Enable terminal with the
direction controlled by the defined FWD. REV defi ne the direction.
K
FWD/REV switch
S W1
R UN butt on
SW2
STOP but ton
EN i s defini ng t he corresponding t erminal function as Funct ion 3
Three-wire operation cont rol
.
:
:
:
“
”
Fig. 6-10 Three-wire operation mode 1
K
OFF
ON
Ope ration
Command
FWD
R EV
Sx(FW D)
Sx(E N)
S x(REV)
DCM
SW 1
SW2
K
DZB
Series
-4 8 -
BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT
BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT
BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT
BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT
BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT
BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT BLUE ELEPHANT