background image

 

 

GETTING STARTED 

 

I n i t i a l   s e t - u p  

 
1.  Open all cartons and locate inlet, hose, hose clamps and wheels.  Refer to Table 1 for the applicable part 

numbers for your model. 

2.  Remove ALL filters and packing materials from cartons and the unit cabinet. 

3.  Place the unit on its side and install wheels in the bottom plate. 

4.  Attach the inlet to the top of the lid with the six screws provided. 

5.  Remove plastic wrap from gas/odor filter (refer to Table 1 for filter part numbers). 

6.  Place gas/odor filter into the bottom of the cabinet and secure with the provided threaded rod, retaining plate, 

and wingnuts (NOTE: Pay attention to direction of airflow arrow). 

7.  Place the FX7 pre-filter on top of the gas/odor filter. 

8.  Close and latch the lid. 

9.  Attach power cord to the power receptacle located on the lower rear of the cabinet. 

 

 

L o c a t i n g   t h e   a i r   c l e a n e r  

 
Placing the GS2-200 unit as close as possible to the pollution source reduces the amount of ducting needed, 

reduces back-pressure, lowers power consumption, and improves overall performance.  Placement should 

minimize hose length and the number of bends.  Use capture hoods with high efficiency entry whenever 

possible.  The unit exhausts through the bottom panel make sure to allow for adequate ventilation.   

 

I n l e t   h o s e   a t t a c h m e n t  

 

The GS2-200 unit ships standard with a 1 x 2”, 2 x 2” or 1 x 3” inlet. Attach flex hose over the metal air inlet tube 

and tighten securely with the stainless-steel clamp.  Connect the hose to a Fumex suction hood or place as close 

as possible to the pollution source. 

 

E l e c t r i c   p o w e r

 

 

GS2-200 series is manufactured with a universal blower/motor assembly (90-250/1/50-60) and must only use a 10-

Amp fuse.  Default power cord/plug is US (120V).  Contact Fumex for additional information or options. 

 
 
 
 
 
 
 

Confirm that correct power supply is available. 

 
 
 

Summary of Contents for GS2-200

Page 1: ...any solid state speed control device WARNING For general ventilating use only Do not use to exhaust hazardous or explosive materials or vapors WARNING Use only a 10 Amp fuse CAUTION Do not operate wit...

Page 2: ...o c a t i n g t h e a i r c l e a n e r Placing the GS2 200 unit as close as possible to the pollution source reduces the amount of ducting needed reduces back pressure lowers power consumption and im...

Page 3: ...Filter and then press the FILTER RESET button If the light remains illuminated or turns off and comes back on then contact Fumex for assistance The GS2 200 unit contains a VOC sensor to detect odors...

Page 4: ...s commonly found in industrial manufacturing processes Part FX4 Blend of FX1 with FX2 for broad spectrum gas treatment SELECTING GAS ODOR ADSORBENT FILTERS Media Selection and Service Life Fumex offer...

Page 5: ...tions only 10 Amp fuse and check the product If the replacement fuse blows a short circuit may be present and the product should be discarded or returned to an authorized service facility for examinat...

Page 6: ...returned PREPAID to Fumex LLC 1150 Cobb International Pl Kennesaw GA 30152 There are no warranties which extend beyond the descriptions set forth in this warranty notwithstanding any knowledge of Fume...

Page 7: ...flash drive with a configuration file and the USB port on the control board Contact Fumex to acquire the correct configuration file for your unit 8 Reprogram the software by changing the remoteSwitchO...

Page 8: ...ia a flash drive with a configuration file and the USB port on the control board Contact Fumex to acquire the correct configuration file for your unit 8 Reprogram the software by changing the remoteSw...

Page 9: ...9 DRAWINGS AND FIGURES Figure 1...

Page 10: ...10 DRAWINGS AND FIGURES Figure 2 Figure 3 ON OFF Relay Activation Switch...

Reviews: