CONTROLS
On/Off Switch
Simple one touch controls – The green light above the POWER button will illuminate confirming power to the
unit.
Blower/Fan
The GS2-200 unit utilizes a variable speed blower with three speed settings. Press the up and down arrow
buttons to increase/decrease blower speed. A green light next to the specific speed (Low, Med, or High) will
indicate speed setting. In the case of a blower failure, all 3 blower speed lights will flash. To reset the blower’s
internal thermal protection, disconnect the unit momentarily from its power source and reconnect. If the lights
continue to flash contact Fumex LLC. for replacement information.
Filter monitoring
The GS2-200 unit utilizes a pressure differential switch to monitor the status of the Pre-filter. The system
monitors across all filters simultaneously and the Red “FILTER” light will illuminate when the Pre-filter needs to
be replaced. The recommended procedure is to replace the Pre-Filter and then press the “FILTER RESET” button.
If the light remains illuminated or turns off and comes back on then contact Fumex for assistance.
The GS2-200 unit contains a VOC sensor to detect odors/gases in the exhaust stream. When the gas/odor filter
becomes saturated and breakthrough of the VOC occurs the “GAS” warning light will illuminate.
GENERAL FILTER CARE
Fumex’s GS2-200 air purifier features a multi-stage filtration system designed to remove a wide range of
pollutants from the process plume in an extremely efficient, cost-effective manner. The sytem utilizes a pressure
differential switch to indicate blocked / clogged filters. Once the warning lights illuminate, filters should be
checked and clogged filters replaced.
S T A N D A R D F I L T E R S :
Part # FX7 – Polyester pre-filter
The disposable polyester pre-filter is the first stage of the filtration process. Its main function is to remove dust
particles 100
µ
and larger in advance of the more expensive pleated panel filter.
Replacement:
The service life of the polyester pre-filter is determined by the type and volume of large particles collected.
Average service life is 4-6 weeks