– Gas/Odor Filter
Most process plumes contain several gases, some odorous
– some not, some toxic at elevated concentrations
– some completely harmless regardless of concentration. To ensure employee safety the type and
concentration of pollutants must be determined. Please contact Fumex Engineering for filter selection
assistance. These filters utilize a blended activated carbon and activated alumina impregnated with KMnO4
filter to capture and treat gases/odors. This combination of materials provides protection across a broad range
of gases commonly found in industrial manufacturing processes.
GENERAL MAINTENANCE
1) The blower motor(s) is a sealed unit, 24,000 hr. MTBF rated. It is permanently lubricated and does not require
oiling
– keep it free of dust accumulations to prevent overheating.
2) Remove any loose accumulations of dust/debris from the air filter chamber periodically.
“This product employs overload protection (fuse). A blown fuse indicates an overload or short-circuit situation. If
the fuse blows, unplug the product from the receptacle. Replace the fuse as per the user servicing instructions
(use only 20-Amp fuse) and check the product. If the replacement fuse blows, a short circuit may be present, and
the product should be discarded or returned to an
authorized service facility for examination and/or repair”.
Remote Interface and Connectivity Function
The GS3-500 can be supplied with an optional interface package providing remote start/stop and filter monitoring
capabilities (Part # FA227). Please see instructions below for Relay Activation/De-Activation procedures and
refer to the drawing in Figure 1 for remote connections.
WARNING
“To Prevent the Risk of Electrical Shock, Connect Remote Interface
Cable to 24v, Class 2 Power Supply
Only”
WARNING
“Disconnect from All Power Supplies Before Servicing”