– Gas/Odor Filter 

Most process plumes contain several gases, some odorous 

– some not, some toxic at elevated concentrations 

–  some  completely  harmless  regardless  of  concentration.    To  ensure  employee  safety  the  type  and 
concentration  of  pollutants  must  be  determined.    Please  contact  Fumex  Engineering  for  filter  selection 

assistance.    These  filters  utilize  a  blended  activated  carbon  and  activated  alumina  impregnated  with  KMnO4 

filter to capture and treat gases/odors.  This combination of materials provides protection across a broad range 

of gases commonly found in industrial manufacturing processes. 

 

GENERAL MAINTENANCE 

 

1)  The blower motor(s) is a sealed unit, 24,000 hr. MTBF rated.  It is permanently lubricated and does not require 

oiling 

– keep it free of dust accumulations to prevent overheating. 

2)  Remove any loose accumulations of dust/debris from the air filter chamber periodically. 

 

 
“This product employs overload protection (fuse). A blown fuse indicates an overload or short-circuit situation. If 
the fuse blows, unplug the product from the  receptacle. Replace the fuse as per the user servicing instructions 

(use only 20-Amp fuse) and check the product. If the replacement fuse blows, a short circuit may be present, and 

the product should be discarded or returned to an 

authorized service facility for examination and/or repair”.

 

 

Remote Interface and Connectivity Function 
 

The GS3-500 can be supplied with an optional interface package providing remote start/stop and filter monitoring 

capabilities  (Part  #  FA227).    Please  see  instructions  below  for  Relay  Activation/De-Activation  procedures  and 

refer to the drawing in Figure 1 for remote connections.  

 

 

 
 
 
 
 
 

WARNING 

“To Prevent the Risk of Electrical Shock, Connect Remote Interface 

Cable to 24v, Class 2 Power Supply 

Only” 

 

 

 

 

 

 

WARNING 

“Disconnect from All Power Supplies Before Servicing” 
 
 
 
 
 
 

Summary of Contents for GS3-500 Series

Page 1: ...ith any solid state speed control device WARNING For general ventilating use only Do not use to exhaust hazardous or explosive materials or vapors WARNING Use only a 20 Amp Fuse CAUTION Do not operate...

Page 2: ...minimize hose length and the number of bends Use capture hoods with high efficiency entry whenever possible The unit exhausts through the bottom panel make sure to allow for adequate ventilation I n...

Page 3: ...s loaded Red lights will indicate that a filter change is necessary The GS3 500 contains a VOC sensor to detect odors gases in the exhaust stream The system continually monitors the exhaust stream whi...

Page 4: ...any loose accumulations of dust debris from the air filter chamber periodically This product employs overload protection fuse A blown fuse indicates an overload or short circuit situation If the fuse...

Page 5: ...nternational Pl Kennesaw GA 30152 There are no warranties which extend beyond the descriptions set forth in this warranty notwithstanding any knowledge of Fumex LLC regarding the use or uses intended...

Page 6: ...and the USB port on the control board Contact Fumex to acquire the correct configuration file for your unit 8 Reprogram the software by changing the remoteSwitchOnly setting in the configuration file...

Page 7: ...ration file and the USB port on the control board Contact Fumex to acquire the correct configuration file for your unit 8 Reprogram the software by changing the remoteSwitchOnly setting in the configu...

Page 8: ...8 DRAWINGS AND FIGURES Figure 1...

Page 9: ...9 DRAWINGS AND FIGURES RELAY ACTIVATION SWITCH OFF ON Figure 2 Figure 3...

Reviews: