1-A. Preliminary/Final Checking and
Alignment of Tape Path
Purpose:
To make sure that the tape path is well stabilized.
Symptom of Misalignment:
If the tape path is unstable, the tape will be damaged.
Note: Do not use an Alignment Tape for this procedure.
If the unit is not correctly aligned, the tape may be
damaged.
1. Play back a blank cassette tape and check to see
that the tape runs without creasing at Guide Roll-
ers [2] and [3], and at points A and B on the lead
surface. (Refer to Fig M3 and M4.)
2. If creasing is apparent, align the height of the guide
rollers by turning the top of Guide Rollers [2] and
[3] with a Guide Roller Adj. Screwdriver. (Refer to
Fig. M3 and M5.)
Note: Beneath each Guide Roller, there is a
small screw. (Refer to Fig. M5.) This screw works
to apply adequate torque to the shaft of each
Guide Roller so that the Guide Roller turns prop-
erly. Even when adjusting the height of the Guide
Roller(s), do not touch these two small screws.
3. Check to see that the tape runs without creasing at
Take-up Guide Post [4] or without snaking be-
tween Guide Roller [3] and AC Head.
(Fig. M3 and M5)
4. If creasing or snaking is apparent, adjust the Tilt
Adj. Screw of the AC Head. (Fig. M6)
1-B. X Value Alignment
Purpose:
To align the Horizontal Position of the Audio/Con-
trol/Erase Head.
Symptom of Misalignment:
If the Horizontal Position of the Audio/Control/Erase
Head is not properly aligned, maximum envelope can-
not be obtained at the Neutral position of the Tracking
Control Circuit.
1. Connect the oscilloscope to TP301 (C-PB) and
TP501 (CTL) on the Main CBA. Use TP502 (RF-
SW) as a trigger.
2. Play back the Gray Scale of the Alignment Tape
(FL6N8) and confirm that the PB FM signal is pre-
sent.
3. Set the Tracking Control Circuit to the center posi-
tion by pressing the CH UP button then the PLAY
button on the VCR. (Refer to note on bottom of
page 2-3-4.)
4. Use the X-Value Adj. Screwdriver so that the PB FM
signal at TP301 (C-PB) is maximum. (Fig. M6)
5. Press CH UP button on the VCR until the CTL wave-
form has shifted by approx. +2msec. Make sure
that the envelope is simply attenuated (shrinks in
height) during this process so that you will know
the envelope has been at its peak.
Lead Surface of Cylinder
Tape
Fig. M4
Guide Roller
Tape
Correct
Incorrect
Take-up Guide
Post
Tape
Small Screw
Fig. M5
Azimuth Adj. Screw
X-Value Adj.
Screwdriver
Tilt Adj. Screw
AC Head
Fig. M6
Guide Roller [2]
Guide Roller [3]
A
B
Take-up Guide Post [4]
AC Head
Fig. M3
2-3-3
H8740MA
Summary of Contents for 23C-250
Page 22: ...1 8 3 1 8 4 1 8 5 H8624SCM1 Main 1 4 Schematic Diagram...
Page 23: ...1 8 6 1 8 7 1 8 8 H8624SCM2 Main 2 4 Schematic Diagram...
Page 24: ...1 8 9 1 8 10 1 8 11 H8624SCM3 Main 3 4 Schematic Diagram...
Page 25: ...1 8 12 1 8 13 1 8 14 H8624SCM4 Main 4 4 Schematic Diagram Function Schematic Diagram H8743SCF...
Page 26: ...1 8 15 1 8 16 Jack Schematic Diagram H8622SCJ...
Page 27: ...1 8 17 1 8 18 SECAM Schematic Diagram H8624SCS...
Page 30: ...1 8 26 1 8 25 BH8700F01031 Function CBA Top View Function CBA Bottom View...
Page 31: ...1 8 28 1 8 27 BH8700F01021 Jack CBA Top View Jack CBA Bottom View...
Page 32: ...1 8 30 1 8 29 SECAM CBA Top View SECAM CBA Bottom View BH8700F01011 C...
Page 58: ...EXPLODED VIEWS Front Panel A1X 3 1 1 H8743FEX...
Page 60: ...Packing Some Ref Numbers are not in sequence S2 S2 X4 S1 X1 X2 X20 X3 Unit S3 3 1 3 H8740PEX...
Page 78: ...23C 250 23C 250A H8743FP Printed in Japan 2001 04 20 HO...