5-1
FL9.1EA
ELECTRICAL ADJUSTMENT INSTRUCTIONS
General Note: “CBA” is abbreviation for
“Circuit Board Assembly.”
Note:
Electrical adjustments are required after
replacing circuit components and certain
mechanical parts. It is important to perform
these adjustments only after all repairs and
replacements have been completed.
Also, do not attempt these adjustments unless
the proper equipment is available.
Test Equipment Required
1. NTSC Pattern Generator (Color Bar W/White
Window, Red Color, Dot Pattern, Gray Scale,
Monoscope, Multi-Burst)
2. Remote control unit
3. Color Analyzer
How to make the Service remote
control unit:
[LC320SLX, LC320EMX, LC320EMXF]
Cut “A” portion of the attached remote control unit as
shown in Fig. 1.
[32MF339B/F7, 32MF369B/F7]
Cut “A” portion of the attached remote control unit as
shown in Fig. 2.
[LC320SSX, LC321SSX]
Cut “A” portion of the attached remote control unit as
shown in Fig. 3
How to set up the service mode:
Service mode:
1. Use the service remote control unit.
2. Turn the power on.
3. Press the service button on the service remote
control unit. The following screen appears.
Fig. 1
service button
(There is a button under the plastic housing.)
A
Fig. 2
service button
(There is a button under the plastic housing.)
A
Fig. 3
service button
A
Code :
Pic code :
MIPS :
***********-***
**-***-**-*****-***
Push 0key
Tuner :
Safety :
****-*****-****
safety_Non
"*" differs depending on the models.
Summary of Contents for 32MF339B/F7
Page 63: ...10 8 A91FSSCM2 Power Supply 2 4 Schematic Diagram LC321SSX 32MF369B F7 ...
Page 64: ...10 9 A91FSSCM3 Power Supply 3 4 Jack Schematic Diagram LC321SSX 32MF369B F7 ...
Page 65: ...10 10 A91FSSCM4 Power Supply 4 4 Schematic Diagram LC321SSX 32MF369B F7 ...
Page 68: ...10 13 A91F3SCF Function Schematic Diagram LC320SLX 32MF339B F7 LC320SSX LC320EMX LC320EMXF ...
Page 69: ...10 14 A91FSSCF Function Schematic Diagram LC321SSX 32MF369B F7 ...
Page 71: ...10 16 A91FSSCIR IR Sensor Junction Schematic Diagram LC321SSX 32MF369B F7 ...