System
bintec User’s Guide
17
Submenu Schedule & Monitor
4
If
W
HAT
TO
MONITOR
:
interfaces
has been selected, the
K
EEPALIVE
M
ONITORING
➜
ADD/EDIT
menu consists of the following fields:
Field
Description
Interface
Defines the interface to be monitored in the
gateway.
Enter the interface
I
NDEX
here. The
I
NDEX
can
be determined, for example, with the command
ifstat
.
Default value:
0.
Trigger
Defines the status of
I
NTERFACE
, which initiates
a certain
A
CTION
.
Possible values:
■
down
: Interface is deactivated (default val-
ue)
■
up
: Interface is activated
Action
Defines the action that is to follow the status
defined in
T
RIGGER
. The action is executed on
the interface range from
F
IRST
I
F
I
NDEX
and
F
IRST
I
F
I
NDEX
+
R
ANGE
.
Possible values:
■
none:
No action (default value)
■
down
: Deactivation of interface(s)
■
up
: Activation of interface(s)