System
bintec User’s Guide
5
System Menu
1
Table 1-1:
S
YSTEM
menu fields
Message Level for the
Syslog Table
Specifies the priority of the syslog messages to
be recorded internally. Possible values:
■
emerg
: emergency messages (highest pri-
ority)
■
alert
: alert messages
■
crit
: critical messages
■
err
: error messages
■
warning
: warning messages
■
notice
: notice messages
■
info
(default value): info messages
■
debug
: debug messages (lowest priority)
Syslog messages are only recorded internally if
they have a higher or identical priority to that
indicated, i.e. all messages generated are
recorded at syslog level
debug
.
Maximum Number of Sys-
log Entries
Maximum number of syslog messages saved
internally in the gateway
(possible values:
0
...
1000
).
Default value:
20
.
You can show the saved messages in the
Setup Tool under
M
ONITORING
AND
D
EBUGGING
➜
M
ESSAGES
.
Maximum Number of
Acctlog Entries
Maximum number of accounting messages
saved internally in the gateway
(possible val-
ues:
0
...
1000
).
Default value:
20
.