The System Management->Remote Authentication-> ->Newmenu consists of
the following fields:
Fields in the Basic Parameters menu
Field
Description
Authentication Type
Displays which function is to be used. The value
cannot be changed.
Possible values:
•
2$ 0%
: Here, you can define whether the
current server is to be used for login authentication
to your device.
Server IP Address
Enter the IP address of the server that is to be re-
quested for login authentication.
Secret
Enter the password to be used to authenticate and, if applic-
able, encrypt data exchange between the server and
the network access server (your device). The maximum length
of the entry is 32 characters.
Priority
Assign a priority to the current server. The server
with the lowest value is the one used first for login
authentication. If there is no response or access is denied (only
if Policy =
*!
), the entry with the next-
highest priority is used.
The available values are
to
, the default value is
.
Entry active
Select whether this server is to be used for login authentication.
The function is activated by selecting
#/
.
The function is enabled by default.
The menu Advanced Settings consists of the following fields:
Fields in the Advanced Settings menu
Field
Description
Policy
Select the interpretation of the response.
Possible values:
•
*!
(default value): The serv-
10 System Management
Funkwerk Enterprise Communications GmbH
106
bintec Rxxx2/RTxxx2