Fig. 54:
Physical Interfaces
+
SHDSL
->
SHDSL Configuration
->
Fields in the SHDSL Parameters menu
Field
Description
ATM Interface
Displays the name of the ATM interface.
Device Mode
Define the role within the connection.
Possible values:
•
4 4& && F,"
(default value):
Mode for the user page of the SHDSL connection.
•
4? 4/ ? %"
: Mode for the provider page of the
SHDSL connection.
Note: CPE on the one hand and CO on the other hand must al-
ways be set for each SHDSL connection. All the pairs of wires
should also be set to the same mode - no mixed mode is pos-
sible.
SHDSL Type
Define which Annex of ITU-T Recommendation G.991.2 is used
for the connection.
Possible values:
•
0= 0
: For applications in North America
(provider-dependent).
•
0= >
(default value): For applications in Europe
(provider-dependent) for example.
Funkwerk Enterprise Communications GmbH
11 Physical Interfaces
bintec Rxxx2/RTxxx2
143