FTH-KBF1
CONTACT
FUNTIN HOME NATURAL GAS DETECTOR MANUAL
Websit :
https
://
www
.
funtintech
.
com
Tel :
86 13760453400
eMail:
support@funtin.cn
Address :
B201 4F Niulanqian Build Baoan
District Shenzhen, China
Zip :
518000
Welcome to follow our facebook:
https
://
www.facebook.com/funtintech
green/red indicator
yellow indicator
button
LED display
USB charge
After power on, the detector self examines, then enters
the preheating state, the preheating state continues 180s,
at this time the detector has no monitoring function.
After the preheating is over, the detector enters the
normal monitoring state. Under this condition, the detector
will inspect itself by pressing the key.
When the indoor gas or LPG gas concentration exceeds
the alarm value, the detector enters the alarm state, and
the normal monitoring state is restored when the indoor
gas or LPG concentration is lower than the alarm value.
When the sensor failure, the detector will enter the
failure state, re power off, again on power, if still a state of
failure, please call after-sales service phone for
maintenance.
3.
Function Introduction
Installation method
Installation method A (adhesive back glue)
1
)
Used for ceramic tile, glass, wood new building materials,
stainless steel and other wall.
2
)
Before installation, please keep the wall clean.
3
)
Please install and fix the location before installing.
4
)
Please stick to the equipment and keep it for more than 10
seconds to maintain.Paste stability.
Installation method B (hanging nail)
1) Suitable for cement surface, putty wall, etc.
2
)
Fix the equipment on the nail according to the
position of hanging hole.
PS1:
Attach the wall plate to a groove in the back of the main engine
.
PS2:
The installation is completed by rotating the wall plate in accordance with the indicated
direction of the groove
.
PS3:
5V MicroUSB interface charging line is used for power supply
.
PS1
PS2
PS2
The independent combustible gas detector FTH
-
KBF1,
measuring 0~100%LEL, is an intelligent monitoring device
for natural gas and liquefied petroleum gas. The alarm and
red warning signals will be issued once the concentration
of the monitored gas reaches a dangerous level due to
leakage and other reasons. Ensure that gas leakage
information is transmitted promptly and without dead ends,
while closing the solenoid valve, cutting off the leakage
source and protecting the user's family safety.
1
. Product Introduction
Self check status:
Green, red and yellow indicator
lights turn out in turn, then LCD screen gradually displays
"8.88", and finally buzzer rings.
Preheating state:
Green indicator lights flicker once
per second.
Normal monitoring status:
The green indicator
gradually darkens, then gradually brightens and circulate
repeatedly.
Alarm status:
Red indicator is fast flashing, buzzer
ringing quickly, LCD display methane concentration value
(unit:%LEL).
Fault status:
Yellow indicator lights flicker, buzzer once
a second, LCD screen shows "Err".
2.
Indicator State Description
4.
Installation Instructions
Installation Location
≤0.3m
≤5m
1
.
Equipment and gas cookers
should be located in the same
indoor space;
2.Equipment distance from
flammable gas leakage is best
maintained at 1 to 3 meters;
3.It should be fixed at a fixed
position at a height of 30
centimeters from the ceiling.